• +91-85699-09696

HP Codemaster Defibrillator Manufacturer,Supplier and Exporter in India

HP Codemaster Defibrillator

Product Code : EL-ED-3930
Jlab Export is a leading HP Codemaster Defibrillator Manufacturer,and suppliers in India

The HP Codemaster is a defibrillator: it builds up a charge and delivers a controlled shock through its paddles. JLab supplies this HP unit to hospitals and to biomedical engineering colleges for training. It stands 20 cm high, 30 cm wide and 39.7 cm long, and weighs 10.9 kg, so it fits on a crash-cart shelf.

Specifications

BrandHP
Dimensions (H x W x L)20 x 30 x 39.7 cm (7.9 x 11.8 x 15.6 in)
Weight10.9 kg (24 lb)
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
Supplied byJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises in Biomedical Training

A first exercise is identification: students read the make and model label, list the controls and connectors, and write down what each one does. They check the mains lead with a Digital Multimeter for continuity and look over the paddle cables for cuts or worn insulation. Then they power the unit up and note any message it shows during its start-up check.

Under the tutor, students then discharge the paddles into a test load and record whether the unit charged and fired. Nursing students can rehearse switching on, paddle placement and the clear call on a CPR Training Manikin (Adult), with no charge delivered.

Frequently Asked Questions

How much space and weight should I allow for?
The unit weighs 10.9 kg, or 24 lb, and measures 20 x 30 x 39.7 cm. Allow a firm shelf or cart top of at least that size, with room around it for the paddles and cables.

What should I do if it shows a failure message at power-up?
Switch it off, wait a short time and switch on again. If the same message comes back, label the unit out of service and pass it to a biomedical technician. Do not use it for training shocks until it has been checked.

What should the paddle plates look like before use?
Clean, dry and smooth, with no dried gel, pitting or corrosion on the metal. Wipe the plates after every use and look at them at each routine check. Report a pitted or corroded plate to the biomedical team.

Who should open or service it?
Only a trained biomedical technician, working from the service manual. A defibrillator stores high voltage inside, and the charge can remain after the unit is switched off, so students must not open the case.

Other Defibrillators

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us