HP Codemaster Defibrillator Manufacturer,Supplier and Exporter in India
Product Code : EL-ED-3930
Jlab Export is a leading HP Codemaster Defibrillator Manufacturer,and suppliers in India
The HP Codemaster is a defibrillator: it builds up a charge and delivers a controlled shock through its paddles. JLab supplies this HP unit to hospitals and to biomedical engineering colleges for training. It stands 20 cm high, 30 cm wide and 39.7 cm long, and weighs 10.9 kg, so it fits on a crash-cart shelf.
Specifications
| Brand | HP |
| Dimensions (H x W x L) | 20 x 30 x 39.7 cm (7.9 x 11.8 x 15.6 in) |
| Weight | 10.9 kg (24 lb) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Supplied by | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises in Biomedical Training
A first exercise is identification: students read the make and model label, list the controls and connectors, and write down what each one does. They check the mains lead with a Digital Multimeter for continuity and look over the paddle cables for cuts or worn insulation. Then they power the unit up and note any message it shows during its start-up check.
Under the tutor, students then discharge the paddles into a test load and record whether the unit charged and fired. Nursing students can rehearse switching on, paddle placement and the clear call on a CPR Training Manikin (Adult), with no charge delivered.
Frequently Asked Questions
How much space and weight should I allow for?
The unit weighs 10.9 kg, or 24 lb, and measures 20 x 30 x 39.7 cm. Allow a firm shelf or cart top of at least that size, with room around it for the paddles and cables.
What should I do if it shows a failure message at power-up?
Switch it off, wait a short time and switch on again. If the same message comes back, label the unit out of service and pass it to a biomedical technician. Do not use it for training shocks until it has been checked.
What should the paddle plates look like before use?
Clean, dry and smooth, with no dried gel, pitting or corrosion on the metal. Wipe the plates after every use and look at them at each routine check. Report a pitted or corroded plate to the biomedical team.
Who should open or service it?
Only a trained biomedical technician, working from the service manual. A defibrillator stores high voltage inside, and the charge can remain after the unit is switched off, so students must not open the case.
Other Defibrillators
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 12 November 2026