ICU Bed Manual Manufacturer,Supplier and Exporter in India
Product Code : EL-HB-1978
Jlab Export is a leading ICU Bed Manual Manufacturer,and suppliers in India
Every movement of this ICU bed is set by hand, with no motor or mains lead. A smooth crank mechanism raises the backrest and knee rest and gives the Trendelenburg and reverse Trendelenburg tilts, and the bed height can be changed. The top is 1.25 mm perforated CRCA sheet, and the stainless steel bows with laminated panels lift off.
Specifications
| Top | 1.25 mm thick CRCA sheet, uniformly perforated |
| Base and main frame | Steel tubes |
| Movements by crank | Backrest, knee rest, Trendelenburg and reverse Trendelenburg |
| Height | Adjustable |
| Castors | 125 mm dia, swivelling, two with brake |
| Bows | Stainless steel with laminated panels, removable |
| Fittings | Stainless steel saline rod with four locations, protective stainless steel railing |
| Finish | Epoxy powder coated |
| Dimensions | 2150 L x 900 W x 810 H mm |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Nursing Lab Exercises with Crank Beds
Students learn the bed by working each crank in turn and calling out which section moves. They then turn an Elderly Fully-Functional Nursing Manikin onto its side with the railing raised on the far side, behind a Ward Screen for privacy.
Another drill sets the bed for a meal: backrest raised, knee rest slightly raised and a Bed Side Locker within reach. Students finish by lowering the sections, setting both castor brakes and wiping the railing and bows.
Frequently Asked Questions
Does this ICU bed need electricity?
No. All the movements are worked by hand cranks, so it keeps working during a power cut and needs no socket near the bed. It suits wards where the supply is unreliable.
What if a crank becomes hard to turn?
Stop turning and check that nothing is caught under the moving section and that the patient is not pressing against it. A crank that stays stiff or grinds needs cleaning and lubrication of the mechanism by a trained technician.
How do I avoid trapping fingers at the railing?
Keep hands clear of the joints when raising or lowering the stainless steel railing, and check that the patient’s hands are inside the bed first. Make sure the railing is fully latched before walking away.
How many castors have brakes?
Two of the 125 mm swivelling castors are braked. Set both before cranking any section or moving the patient, and check the bed does not roll when pushed.