On this intensive care bed, actuators drive the backrest, knee rest and head-down or head-up tilt, so each section moves smoothly. The bed height also adjusts, between 530 and 760 mm. The perforated CRCA sheet top sits on a steel tube frame, the swivelling castors lock centrally, and the ABS head and foot bows lift off for access to the patient.
Specifications
| Overall size | 2160 L x 1015 W x 530 to 760 H mm |
| Mattress size | 198 L x 90 W cm |
| Top | CRCA sheet, uniformly perforated |
| Base and main frame | Steel tubes |
| Movements by actuators | Backrest, knee rest, Trendelenburg and reverse Trendelenburg |
| Height | Adjustable |
| Castors | 125 mm dia, swivelling, central locking |
| Bows | ABS, removable |
| Fittings | Stainless steel saline rod with four locations, ABS protective railing |
| Finish | Epoxy powder coated |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
ICU Training Lab Exercises
Nursing students run a mock cardiac arrest drill on the bed. They lower the backrest flat, lift off the head bow and bring a Crash Cart to the bedside, then start compressions on a CPR Training Manikin (Adult). The drill also covers setting the central castor lock before the first compression.
In a biomedical-engineering lab, students run each actuator through its travel, listen for jerky or noisy movement and check that the height stops at both ends. They also refit the saline rod in each of its four locations.
Frequently Asked Questions
Which movements do the actuators drive?
They move the backrest, the knee rest, and the Trendelenburg and reverse Trendelenburg tilts. The bed height also adjusts between 530 and 760 mm, so staff can lower it for transfers and raise it for close observation.
Why would just one movement stop working?
If the other movements still work, the fault is usually in that one actuator, its cable or the control. Take the bed out of use and let a trained technician test it, rather than forcing the section by hand.
How does central locking help?
Central locking sets the brakes on all the castors together, from one control. The bed cannot creep away during a transfer or a resuscitation, and staff do not have to bend to each wheel.
What mattress size fits this bed?
The frame takes a mattress of 198 x 90 cm. A smaller mattress leaves gaps at the railing where a limb can be trapped, so match the size before the bed goes into use.