LED Phototherapy Stand Manufacturer,Supplier and Exporter in India

LED Phototherapy Stand

Product Code : EL-NP-4022
Jlab Export is a leading LED Phototherapy Stand Manufacturer,and suppliers in India

This phototherapy stand carries a head of blue LEDs on a mobile, height-adjustable stand. The LEDs emit at 450–470 nm, give off no infrared and draw 12 W. The head swivels, so the stand can be used beside a radiant warmer or an infant trolley, and it runs on 100–250 V AC.

Specifications

Light sourceBlue LEDs, 450–470 nm
Power consumption12 W
Infrared outputNone
LED lifeOver 20,000 hours
StandMobile, on casters, height adjustable
Lamp headSwivelling, for use with a radiant warmer or infant trolley
ConstructionMild steel, powder coated
Time totaliserOptional
Supply100–250 V AC, 50 Hz
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Skills Lab and Workshop Practice

Biomedical-engineering students run a light-output check. With the head fixed at one height, they hold a Digital Lux Meter at several points underneath and map how the reading falls towards the edges. A lux meter is weighted to the eye and reads blue light poorly, so the map is only a relative one. Clinical output checks use a radiometer made for the blue band.

Nursing students practise moving the stand on its casters, setting the head height and swivelling the head over a Nursing Baby Unisex lying in an Infant Bed. They finish by checking the casters and the height adjustment before parking the stand.

Frequently Asked Questions

Why is the power draw only 12 W?
LEDs put their light into a narrow blue band and give off no infrared, so less input is wasted than in a lamp that also radiates heat. The whole head draws 12 W, a small load on the ward circuit.

Can a lux meter check the light output?
Only as a rough comparison. A lux meter is weighted to the human eye and reads blue light poorly. Phototherapy output is checked with a radiometer made for the blue band, at the distance the hospital’s own protocol sets.

What makes the LEDs flicker?
Flicker usually comes from a loose plug or connector, a supply outside 100–250 V, or a failing LED driver. Check the lead and socket first, then have a technician test the driver if the flicker continues.

How is the head height set?
Release the height adjustment on the stand, raise or lower the head, then secure it again. The distance to the baby is set by trained staff to the hospital’s own protocol. Swivel the head when the stand is beside a warmer or trolley.

What routine maintenance does the stand need?
The LED head has no tubes to change, so care is mostly mechanical. Check that the casters roll and stop freely, that the height adjustment holds, and that the powder coat has no chips where rust could start.