A manifold gauge set joins the low and high side service ports of an air conditioning system. One tool then reads both pressures and controls evacuation, charging and recovery. This diagnostic and service set has colour-coded gauges, valves and three hoses. Its quick connect fittings carry a high-pressure safety valve, and a two-piece hose adapter set comes with it.
Specifications
| Use | Diagnosis and service of air conditioning systems |
| Gauges | Easy to read, colour-coded |
| Valves | Colour-coded |
| Hoses | 3, colour-coded |
| Fittings | Quick connect, with high-pressure safety valve |
| Included | 2-piece hose adapter set |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Service Practicals on an Air Conditioning Rig
On the Air Conditioning Test Rig, students connect the blue hose to the low side port and the red hose to the high side. The yellow hose goes to the tool in use. With both valves closed, they read suction and discharge pressures while the rig runs. A pressure-temperature chart for the refrigerant turns each reading into a saturation temperature.
To evacuate, the yellow hose goes to the Small Vacuum Pumps and both valves are opened. For charging, the refrigerant cylinder stands on the Wireless Refrigerant Charging Scale. Students then charge the weight given on the unit plate while watching the low side pressure.
Frequently Asked Questions
How are the three hoses connected?
Blue goes to the low side (suction) port and red to the high side port. The yellow centre hose links the manifold to whichever service tool is in use, such as a vacuum pump, a recovery machine or a refrigerant cylinder.
Why do the valves stay closed while I read pressures?
Each gauge is open to its own hose, so it shows system pressure with the valves shut. Opening a valve connects that side to the centre hose, which is done only to evacuate, charge or recover.
How do I purge air from the charging hose?
With the cylinder connected, open its valve and loosen the yellow hose at the manifold for a moment until refrigerant pushes through, then tighten it. This clears the air and moisture that would otherwise go into the system.
How is a standing vacuum test done?
After evacuation, close both manifold valves and switch off the pump. If the reading holds, the system is dry and tight. A rise that levels off points to moisture boiling off, and one that keeps climbing points to a leak.
What are the two hose adapters for?
They let the hoses join service ports or tools whose fittings differ from the hose ends. The same set can then be used on more than one type of unit.