Mortuary Chamber (Defrosting) Manufacturer,Supplier and Exporter in India
Product Code : EL-MAI-2459
Jlab Export is a leading Mortuary Chamber (Defrosting) Manufacturer,and suppliers in India
Built for hospital mortuaries and anatomy departments, this mortuary chamber can hold its contents below freezing, with a range from -5 °C or -20 °C up to ambient. Stainless steel trays, 200 x 56 x 8 cm, slide out on stainless steel U-rails. A digital controller sets the temperature, and a built-in defrosting system and voltage stabiliser are fitted. Models take one to six bodies.
Specifications
| Inner chamber and tray size | 200 x 56 x 8 cm |
| Trays | Stainless steel, sliding on stainless steel U-rails |
| Outer chamber | Mild steel, painted |
| Temperature range | -5 °C or -20 °C to ambient |
| Controller | Digital temperature controller-cum-indicator |
| Built in | Voltage stabiliser and defrosting system |
| Door | Lockable, magnetic gasket, index card holder |
| Capacity | Models for one, two, three, four or six bodies |
| Power supply | 220 V AC, 50 Hz, single phase |
| Option | Digital controller with computer data logger |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises for Mortuary Trainees
Trainees practise the daily round on an empty chamber. They read the controller display, check it against a Digital Thermometer/Hygrometer placed inside for a few minutes and write both values in the log with the date and time. They also confirm that each door locks and that every index card holder is in place.
A second exercise covers the trays. Working in pairs, trainees slide an empty tray out on its rails, line it up with a Stretcher on Trolley at the same height and slide it back. Cleaning of trays and rails follows the department’s own procedure.
Frequently Asked Questions
What does the defrosting system do?
Frost slowly builds up on the cooling coil, and thick frost stops the coil taking heat out of the chamber. The defrosting system clears it at intervals, so the chamber keeps cooling without being emptied for manual defrosting.
Why is water collecting inside the chamber?
Melt water from defrosting normally runs away through a drain. If the drain line is blocked, it pools inside instead. Have the drain cleared, and check that the door closes fully so moist room air is kept out.
What is the index card holder for?
It holds a card on each door with the details staff need to identify what is stored there and when. Keeping the card and the department register up to date avoids mistakes when trays are moved.
What should be done if the temperature starts rising?
Check that every door is shut and latched, the gasket is sealing and nothing blocks the air paths. Record the reading and time and tell the supervisor. If the temperature cannot be brought back, the institution’s contingency plan applies and a refrigeration technician is called.
Other Mortuary and Anatomy Equipment
- Mortuary Chamber (cooling model, no freezing range)
- Autopsy Table
- Cold Room
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 12 November 2026