Respironics Bipap Pro

Product Code : EL-MAI-4018
Jlab Export is a leading Respironics Bipap Pro Manufacturer,and suppliers in India

A bilevel positive airway pressure unit sends air through a mask at a higher pressure as the user breathes in and a lower one as they breathe out. JLab supplies the Respironics Bipap Pro, a compact, quiet bedside unit. It has a ramp control, automatic start and stop, a mask removal alert, two time meters and a smart card that logs each session.

Specifications

BrandRespironics
TypeBilevel positive airway pressure unit
Start and stopAutomatic on/off
RampLowers the pressure at the start of a session
AlertMask removal indicator
Data cardSmart card records date, time, ramp use and duration of each use
Time metersTwo: total machine use and time at pressure
AltitudeCompensates for altitude changes
PowerUniversal power supply
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
Supplied byJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Training Exercises for Nursing and Biomedical Students

In a nursing skills lab, students name the parts of the unit, fit a mask on the head of a CPR Training Manikin and connect the tubing. They lift the mask away to hear the mask removal alert, and read both time meters before and after a practice run. Settings are never chosen in class: they follow the hospital protocol and trained staff.

Biomedical trainees check the power supply and cord with a Digital Multimeter, inspect the air inlet filter and practise the cleaning routine for mask and tubing. A Hand Held Pulse Oximeter can be added to the station, so students also practise placing the monitoring probe.

Frequently Asked Questions

What should be checked when the unit does not switch on?
Check that the power cord is pushed fully into the unit and the power supply, and that the wall outlet is live. If it still does not start, pass it to the biomedical department. Users should not open the case.

Why does a clogged air filter matter?
The blower draws all its air through the inlet filter. A dirty or blocked filter makes the blower work harder, run hotter and sound louder. Inspect it on a set schedule and replace it when it looks grey or damaged.

How are the mask and tubing cleaned?
Wash the mask daily and the tubing weekly in warm water with mild soap, rinse well and let them air dry out of direct sun. Follow the hospital infection control routine where it differs.

What does the mask removal indicator do?
It can be set to sound when the mask comes off during use, so staff know the air is no longer reaching the user. It may not work with every mask and circuit, or at high altitude.

What do the two time meters show?
One shows the total running time of the machine, which staff use for service intervals. The other shows the time the unit actually spent delivering pressure to the user, which goes in the care record.

Other Respiratory and Monitoring Equipment

For a quote, use Add To Cart or send us a message through the contact page.