• +91-85699-09696

Piercing Valve Manufacturer,Supplier and Exporter in India

Image Not Found .

Product Code : EL-AELE-12915
Jlab Export is a leading Piercing Valve Manufacturer,and suppliers in India

A piercing valve gives a sealed copper line a service port without brazing. It clamps round the tube, a pin pierces the wall, and the outlet then works like any access valve. This brass valve fits 1/4, 5/16 and 3/8 in tube, has a 1/4 in SAE male flare outlet and comes with a hex key.

Specifications

Outlet1/4 in SAE male flare
MaterialBrass alloy
Tube sizes1/4, 5/16 and 3/8 in
IncludedHex key
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Line Tap Practicals for RAC Students

On a refrigerator trainer or a scrap unit, students fit the valve to the process tube or suction line. They tighten it evenly with the hex key and pierce the line. They connect the blue hose of the Manifold Gauges For Refrigeration Systems to the flare outlet and read the standing pressure.

The clamp is then checked for leaks with Bubble Solution For Leak Detection. Teachers can set the fitted valve beside a brazed-in Access Valve and discuss when each one is the better choice.

Frequently Asked Questions

Which tube sizes does the valve fit?
Copper tube of 1/4, 5/16 and 3/8 in outside diameter. Match the valve to the tube, because a loose clamp will not seal round the pierced hole.

What connects to the outlet?
The 1/4 in SAE male flare takes a standard refrigeration charging hose. Through it the system can be read on a manifold gauge set, recovered or charged.

Why use a piercing valve instead of brazing in a port?
It is fitted without heat, so there is no need to recover the charge first or bring a torch near the appliance. That makes it quick for diagnosis on a sealed system.

Can a piercing valve stay on the system?
It can, but many technicians treat it as a port for the job in hand. When the system is next opened, they braze in an access valve, since a brazed joint is harder to disturb than a clamped seal.

How do I check it for leaks?
Pressurise the line, then wet the clamp, the pierced area and the flare outlet with leak-test solution. Watch for growing bubbles, and tighten or refit the valve if any appear.

Other Service Valves and Tools

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 5 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us