Jlab Export is a leading Recovery Cylinders Manufacturer,and suppliers in India
At 50.5 lb, this is the biggest of the three JLab recovery cylinders, meant for a workshop that collects refrigerant from many jobs before sending it on. It has 1/4 in flare couplings for liquid and gas, a float switch for level sensing, and it suits R-410A and R-32.
Specifications
| Size | 50.5 lb |
| Refrigerant use | R-410A and R-32 |
| Service pressure | 400 psi (2.7 MPa) |
| Relief valve | Opens at 600 psi (4.1 MPa) |
| Tank test pressure | 800 psi (5.5 MPa) |
| Air tightness test pressure | 400 psi (2.7 MPa) |
| Couplings | 1/4 in flare, liquid and gas |
| Level switch | Float type |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises in Refrigerant Handling
Because a large cylinder collects refrigerant from several systems, trainees first learn to test each charge. They sample the system with the Refrigerant Analyzer And Identifier and recover only a clean charge of the refrigerant on the cylinder label. A sample that shows air or a mix goes to a separate cylinder.
A second exercise covers what happens after recovery. Students pass the recovered refrigerant through the Refrigerant Recycling Machine, which cleans it by oil separation and filtering, and log the weight added from each job. Teachers use the log to show how close the cylinder is to its fill limit.
Frequently Asked Questions
Does the cylinder need retesting from time to time?
Yes. Refillable pressure cylinders are tested again at intervals set by the cylinder rules where they are used. The date of the last test is stamped on the cylinder. Check it before each filling, and send an out-of-date cylinder for retesting before it holds refrigerant again.
What do the test pressure figures mean?
The tank is tested at 800 psi (5.5 MPa) and its seals for air tightness at 400 psi (2.7 MPa). In use it should stay within its 400 psi (2.7 MPa) service pressure.
How do I know when it is full?
Weigh it and compare the reading with the fill weight worked out for the refrigerant, at about 80 percent of the liquid capacity. The float switch is a second check: wired to a recovery machine that accepts it, it stops the machine at the set level.
How is a cylinder this size moved?
On a cylinder trolley, upright, with the valves closed and their caps fitted. Do not drop it or roll it along the floor, as a knock on a valve can start a leak.
Other Recovery Cylinders and Tools
- Recovery Cylinders (17.99 lb size)
- Recovery Cylinders (28.71 lb size)
- Fast Vacuum Pumps (for evacuating an empty cylinder)
For a quote, use Add To Cart or send us a message through the contact page.