Of the three recovery cylinders in this range, this is the middle size at 28.71 lb. It is a dual-valve cylinder with separate 1/4 in flare couplings for liquid and gas, a float switch and a service pressure of 400 psi (2.7 MPa). It suits R-410A and R-32.

Specifications

Size28.71 lb
For refrigerantsR-410A and R-32
Service pressure400 psi (2.7 MPa)
Relief valve setting600 psi (4.1 MPa)
Tank test pressure800 psi (5.5 MPa)
Air tightness test pressure400 psi (2.7 MPa)
Liquid and gas couplings1/4 in flare
Float switchFitted
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Push-Pull Recovery Practicals

Larger charges are often moved by push-pull recovery, and this cylinder has the two couplings the method needs. On a unit such as the Split Air-Conditioner, trainees connect the system liquid line to the cylinder liquid coupling. The Refrigerant Recovery Machine then draws vapour from the cylinder gas coupling and pushes it into the vapour side of the system. That pressure drives liquid across into the cylinder.

When the liquid stops moving, the class switches to vapour recovery to take out what is left, reading the pressures on Manifold Gauges for Air Conditioning. Teachers can then show how to work out the fill weight for this cylinder and check it on a scale.

Frequently Asked Questions

How much refrigerant can this cylinder take?
Its size is 28.71 lb, but the safe fill depends on the refrigerant, because liquids differ in density. Work out the weight for about 80 percent of the liquid capacity with that refrigerant, then weigh the cylinder as it fills.

What does the relief valve do?
It opens if the pressure inside reaches 600 psi (4.1 MPa), for example when an overfilled cylinder is left in the heat. It is a last line of protection and no substitute for correct filling and storage.

When is push-pull recovery worth using?
On systems that hold a large liquid charge and have a port on the liquid line. Moving liquid is much faster than recovering the same mass as vapour. Small systems with little liquid are recovered as vapour.

How should a full cylinder be stored?
Upright, with both valves closed and their caps on, away from heaters and direct sun. Label it with the refrigerant it holds and secure it in transport so it cannot roll or fall.