Split Air-Conditioner Manufacturer,Supplier and Exporter in India
Product Code : EL-RACLE-12812
Jlab Export is a leading Split Air-Conditioner Manufacturer,and suppliers in India
A three-phase supply of 380 V runs this large split air conditioner, which is rated at 60,000 BTU on R-410A. It is a non-inverter unit, so the compressor runs at one fixed speed and switches on and off to hold the set temperature. Automatic defrost, independent dehumidification, sleep and timer modes and an LED display are built in.
Specifications
| Type | Split air conditioner, non-inverter |
| Capacity | 60,000 BTU |
| Refrigerant | R-410A |
| Power supply | 380 V, 3 phase, 50 Hz |
| Coil tubing | Internal-thread copper pipe |
| Operating modes | Sleep, timer, independent dehumidification, ECO energy saving |
| Protection and restart | Auto protection, auto restart, anti-cold air |
| Defrost | Automatic |
| Display | LED |
| Noise | Quiet operation |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Workshop Practice on a Three-Phase Split AC
ITI and diploma students can take this unit through a full installation exercise. They mount the indoor and outdoor units, cut and flare the copper lines, and pressure-test the joints with dry nitrogen. They then pull a deep vacuum with the Fast Vacuum Pumps and follow the readings on the Manifold Gauges for Air Conditioning, which carry an R-410A scale.
The 380 V supply makes the electrical work a lesson of its own. Students wire the incoming supply through a Sequence and Phase Fail Relay, which cuts the circuit on phase failure or reversed phases. With the unit running, they read the current in each line with a Digital Clamp Meter and compare the three figures.
Frequently Asked Questions
What does 60,000 BTU mean in tons?
Divide it by 12,000 BTU per hour, the heat that one ton of refrigeration removes, and the answer is 5 tons. That is more than three times the size of the 18,000 BTU home split units, and suits large rooms and halls.
What is the difference between a non-inverter and an inverter AC?
A non-inverter unit like this one runs the compressor at full speed until the room reaches the set point, then stops and starts again as the room warms. An inverter unit changes the compressor speed instead. The fixed-speed type has fewer electronic parts to fault-find.
Can it run on a single-phase supply?
No. It is built for a 380 V, three-phase, 50 Hz supply. A site with only single-phase power needs either a three-phase connection or a smaller single-phase unit.
What do anti-cold air and automatic defrost do?
Both belong to heating on a reverse-cycle unit. In heating the outdoor coil runs colder than the outside air, so frost builds on it. Automatic defrost reverses the cycle for a short time to clear the frost. Anti-cold air keeps the indoor fan off until the indoor coil is warm.
Other Split ACs and Service Items
- Split Air-Conditioner (single-phase inverter heat pump)
- Split Air-Conditioner (single-phase unit on propane)
- R-410A Refrigerant
- Refrigerant Recovery Machine
For a quote, use Add To Cart or send us a message through the contact page.