R-410A Refrigerant Manufacturer,Supplier and Exporter in India
Product Code : EL-MWLE-13028
Jlab Export is a leading R-410A Refrigerant Manufacturer,and suppliers in India
Many split air conditioners run on R-410A, an HFC refrigerant blend that is charged into the system as liquid. This pack holds 11.3 kg in a non-refillable cylinder, for charging practice on air conditioning trainers and for service work on R-410A units.
Cylinder Details
| Refrigerant | R-410A |
| Cylinder | Non-refillable |
| Size | 11.3 kg |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 3–5 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Refrigeration Lab Practicals with R-410A
The standard practical is evacuating and charging a system. Students connect Manifold Gauges for Air Conditioning, whose scale includes R-410A, and pull a vacuum with Fast Vacuum Pumps. They then weigh the liquid charge in from the cylinder standing on a Wireless Refrigerant Charging Scale.
Later sessions cover leak testing every joint with Bubble Solution For Leak Detection. Students also read the suction and discharge pressures against the R-410A temperature scale on the gauges to find the evaporating and condensing temperatures.
Frequently Asked Questions
Why must R-410A be charged as liquid?
It is a blend of two refrigerants that boil at slightly different temperatures. Drawing vapour from the cylinder takes more of one part than the other, so the mix left behind and the mix in the system both change. Liquid charging keeps the blend as made.
Should the cylinder stand upright or be turned over for charging?
Store and move it upright and secured. For liquid charging, check the cylinder: one with a dip tube delivers liquid while upright, and one without must be inverted. Meter the liquid in slowly so it does not reach the compressor as liquid.
Can R-410A be put into an R-22 system?
No. R-410A works at much higher pressures than R-22 and needs a compressor, oil and components built for it. Gauges and hoses must also be rated for R-410A pressures.
What handling care does the cylinder need?
Work in a well-ventilated area, since the vapour is heavier than air and collects in low spaces. Keep the cylinder away from flames, heaters and direct sun. Wear gloves and goggles, because escaping liquid causes cold burns. Never refill the cylinder.
Other Refrigeration Service Tools
- Refrigerant Recovery Machine
- Refrigerant Hose (red, blue and yellow set)
- Infrared Refrigerant Leak Detector
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 5 November 2026