• +91-85699-09696

Resuscitation System Manufacturer,Supplier and Exporter in India

Resuscitation System

Product Code : EL-NE-2040
Jlab Export is a leading Resuscitation System Manufacturer,and suppliers in India

This resuscitation system is an open warmer bed for delivery rooms, intensive care units and operation theatres. A 750 W ceramic heater in a parabolic reflector warms the mattress from above, and a microcomputer controller shows the baby and set temperatures side by side. Suction, a resuscitator, phototherapy and a weighing scale can be added.

Specifications

Heater750 W ceramic element in a parabolic reflector, swivels aside
ControllerMicrocomputer, twin digital displays, LED bar graph of heater output
Control modesBaby-probe control, or manual heater output from 0 to 100%
AlarmsProbe failure, 1 °C high, 1 °C low, high-temperature cut-off, power failure
Baby probeSilicone-sheathed, interchangeable; 28–38 °C range, 0.1 °C resolution
Baby trayTilts ±8° to Trendelenburg and Fowler; acrylic side walls fold up or down
Mattress and working height780 x 490 x 50 mm; 920 mm from the floor
Observation lampHalogen, 12 V, 50 W
Electrical supply230 V ±10%; 750 W heater at full output, 1250 W with phototherapy and lamp on
Weight and castors130 kg; 100 mm castors, two with brakes
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Fittings and Options

A digital Apgar timer is started at birth and gives an acoustic signal at set intervals. An X-ray cassette tray sits under the bed, and the heater box swivels away to make room for an X-ray unit. The optional resuscitator gives manual positive pressure through a mask or tube, with preset pressure limits shown on a manometer. It runs from an air-oxygen mixer or a flow meter.

The optional slow-suction unit uses a diaphragm pump, with a regulator, a vacuum gauge and an unbreakable jar that lifts out. Other options are a halogen phototherapy unit, with three lamps on each side of the heater box, and a built-in digital weighing scale.

Resuscitation Practicals for Nursing Students

Nursing teams run newborn resuscitation drills on an Advanced Infant CPR Training Manikin laid on the bed. Before each drill they switch on the heater and unplug the probe to test its alarm. They also block the suction tubing to watch the gauge rise and aim the observation lamp at the chest.

One student starts the Apgar timer while another starts a Digital Stop Watch, and the class compares the two at each signal. Airway positioning and intubation practice can follow on an Infant Airway Management Model, with the tray tilted and levelled between runs.

Frequently Asked Questions

What should be checked on the station before each delivery?
Switch on and pre-warm the bed, test the probe alarm, block the suction tubing to see the gauge rise, and confirm oxygen flow and the resuscitator manometer. Look over the lamp and the jar too. Your hospital checklist gives the values to use.

Can an X-ray be taken without moving the baby?
Yes. A cassette tray sits under the bed, and the heater box swivels away from the bed to make room for the X-ray unit. The baby stays on the mattress while the cassette is placed and the image is taken.

Which parts are optional?
The resuscitator, the electric slow-suction unit, the halogen phototherapy unit and the built-in weighing scale are options. The heater, controller, baby probe, Apgar timer, tilting bed, X-ray tray and observation lamp come with the basic system.

What does the Apgar timer do?
It is started at the moment of birth and sounds at set intervals afterward. Each signal tells staff that the next Apgar assessment is due, so nobody has to watch a clock during a busy delivery.

How is the suction jar cleaned?
The collection jar is unbreakable and lifts out of the unit. Empty it, wash it and sterilise it as your infection-control rules require, then refit it and check that the lid seals before the next use.

Other Newborn Care Units

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us