These sterile, disposable soft loops pick up a small, fixed volume of sample for streaking and transfers, and go into the waste after one use. They are non-toxic and made with 1 µl or 10 µl loops for semi-quantitative work. A straight inoculation needle is made in the same style for stab cultures.

Specifications

TypeDisposable soft loop
Loop volumes1 µl and 10 µl
Also madeInoculation needle
PropertyNon-toxic
UseHandling samples, semi-quantitative work
Pack quantityPack of 100 (each type)
Minimum order quantity10 packs
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Streak and Stab Inoculation Practicals

For a streak plate, students flame the neck of the broth bottle in a Bunsen Burner flame and dip a 10 µl loop into the culture. They streak one quarter of a Petri Dish Culture plate, then take a fresh loop for each later sector, drawing it out of the last streak. Single colonies appear in the final sector after incubation.

The needle is used for a motility test. Students push it straight down into soft agar in a Glass Culture Test Tube and pull it out along the same line. A sharp stab line after incubation shows a non-motile organism, while hazy spread around it shows motility.

Frequently Asked Questions

Do these loops need flaming before use?
No. They come sterile and are moulded in plastic, so they must never go into a flame. Open the pack close to the work, take a loop by its handle and use it at once. The neck of the culture bottle still needs flaming.

Can a used loop be sterilised and used again?
No, it is a single-use item. Drop each used loop straight into a disinfectant pot or an autoclave bag, and autoclave the waste before it leaves the lab.

When should I use the needle instead of a loop?
Use the needle for stab cultures, such as motility and deep agar tests, and for picking one small colony from a crowded plate. The loop carries more liquid, so it is the better tool for streaking plates and moving broth.

How do I pick up the right volume with a 1 µl or 10 µl loop?
Dip the loop straight down, just below the surface of a well-mixed liquid, and lift it straight out while keeping it upright. A thin film should fill the loop. Tilting it or dipping too deep leaves extra liquid on the stem.

Which loop volume should I choose?
The 10 µl loop carries ten times more liquid, so it suits samples with few bacteria. The 1 µl loop suits dense samples, where a larger drop would give more colonies than can be counted.