Venturimeter and Orificemeter Calibration Set-Up

Product Code : EL-FML-10022
Jlab Export is a leading Venturimeter and Orificemeter Calibration Set-Up Manufacturer,and suppliers in India

Venturimeter and Orificemeter Calibration Set-Up (code EL-FML-10022) is a water re-circulating bench with two pipelines leaving a common manifold, one carrying a clear acrylic venturimeter and the other an orificemeter, both made for 1-inch pipe. A differential manometer reads the pressure difference across whichever meter is in use, and a measuring tank with stopwatch gives the actual flow. This twin-meter calibration bench is manufactured by JLab in Ambala, India.

Specifications

ParameterDetail
MetersVenturimeter and orificemeter, clear acrylic, for 1" dia. pipe
Pipe layoutTwo pipelines in parallel from a common manifold; downstream valves select the meter and regulate flow
Pressure differenceDifferential manometer
Flow controlFlow control valve and by-pass valve
Flow measurementMeasuring tank, 25 litres; electronic stopwatch
Sump tank50 litres
Tank materialStainless steel
Water circulationFHP centrifugal pump
UtilitiesSingle phase, 220 V AC, 0.5 kW; water supply and drain
Quality checkEach calibration set-up is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-FML-10022
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Finding the Coefficient of Discharge

At each flow setting the manometer difference is converted to a head h of flowing water, and Bernoulli’s equation with continuity gives the theoretical discharge Qth = a1 a2 √(2gh) / √(a1² − a2²), where a1 is the pipe area and a2 the throat or orifice area. The measuring tank and stopwatch give the actual discharge Qact, and Cd = Qact / Qth. The venturimeter, with its gradual divergent cone, returns a Cd close to 1, while the orificemeter gives a much lower value because of the vena contracta and the eddy losses behind the orifice.

Using the Meters to Measure Flow

Once Cd is known, either meter measures discharge from its manometer reading alone, Q = Cd × Qth. Plotting Qact against √h for each meter gives a straight line whose slope is the meter constant, which is how the second experiment, discharge measurement through each meter, is carried out. Valves on the downstream side switch the flow between the two pipelines and also set its rate.

Related Flow and Energy Benches

Find more benches like it in Fluid Mechanics Lab, a section of Fluid Mechanics and Hydraulics Lab Equipment.