• +91-85699-09696

Study of Pipe Fitting Manufacturer,Supplier and Exporter in India

Study of Pipe Fitting

Product Code : EL-FML-10023
Jlab Export is a leading Study of Pipe Fitting Manufacturer,and suppliers in India

Study of Pipe Fitting (code EL-FML-10023) is a water re-circulating bench for measuring the head lost in common pipe fittings: a ½-inch bend and elbow, a sudden expansion and a sudden contraction between 15 mm and 25 mm, a ball valve and a gate valve. Pressure tappings at the inlet and outlet of each fitting lead to a differential manometer that shows the pressure loss of that fitting alone. JLab produces this pipe-fittings loss bench in Ambala, India.

Specifications

ParameterDetail
Bend and elbow½" each
Valves½" ball valve and ½" gate valve
Sudden enlargementFrom 15 mm to 25 mm
Sudden contractionFrom 25 mm to 15 mm
Pressure lossDifferential manometer; tappings at inlet and outlet of each fitting
Flow measurementMeasuring tank with piezometer, 25 litres; electronic stopwatch
Sump tank50 litres
Water circulationFHP centrifugal pump, flow control and by-pass valves
UtilitiesSingle phase, 220 V AC, 0.5 kW; water supply and drain
Quality checkEach pipe fitting bench is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-FML-10023
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Loss Coefficient of Each Fitting

The manometer difference across a fitting gives its head loss hL in metres of water. Dividing by the velocity head in the pipe gives the loss coefficient, k = hL / (v²/2g), where v is the measured discharge divided by the pipe bore area. Taking readings at several flow rates, set with the flow control and by-pass valves, shows how steady k stays as the velocity rises.

Sudden Expansion Against Sudden Contraction

For the sudden enlargement from 15 mm to 25 mm, theory gives hL = (v1 − v2)² / 2g from the velocities in the two bores, so the measured loss can be checked against a calculated one. The contraction from 25 mm to 15 mm loses less head, because most of its loss occurs where the jet re-expands just after the vena contracta in the smaller pipe; its k is referred to the velocity in the 15 mm bore.

Head Loss and Pipe Flow Benches

Fluid Mechanics Lab holds the rest of this pipe-flow series, inside Fluid Mechanics and Hydraulics Lab Equipment.