• +91-85699-09696

Water Cooler Trainer Manufacturer,Supplier and Exporter in India

Water Cooler Trainer

Product Code : EL-RAACL-10088
Jlab Export is a leading Water Cooler Trainer Manufacturer,and suppliers in India

Water Cooler Trainer (code EL-RAACL-10088) is a water cooler laid out for study: a 1/3 TR hermetically sealed compressor, a finned air-cooled condenser and a capillary tube feed an evaporator coil wrapped around an insulated stainless steel water tank. Gauges, thermometers, a refrigerant rotameter and an energy meter let students measure the cycle. JLab manufactures this capillary-tube water cooler trainer in Ambala, India.

Specifications

ParameterDetail
CompressorHermetically sealed, 1/3 TR, R-12 refrigerant
CondenserFinned tube, air cooled, forced air flow
Expansion deviceCapillary tube
FilterFilter-cum-drier for the refrigerant
Water tankStainless steel with the evaporator coil wrapped around it, glass wool insulation, insulated lift door at the top; float-operated inlet tap and drain tap
MeasurementsEvaporating and condensing pressure gauges; refrigerant thermometers at condenser and evaporator inlet and outlet; dial thermometer for water; rotameter for liquid refrigerant flow; energy meter for compressor input
ControlsThermostat, pressostat (high/low pressure), compressor overload protector
FinishAnti-corrosion powder coating
ServicesFloor space 1.5 × 1.5 m; water supply 5 litre/min; 230 V, 15 A stabilised AC supply with earthing
Quality checkEach trainer is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-RAACL-10088
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

What Students Measure

The theoretical COP comes from the measured pressures and refrigerant temperatures plotted on a pressure–enthalpy chart: the enthalpy rise across the evaporator divided by the enthalpy rise across the compressor. The rotameter gives the liquid refrigerant flow; converted to mass flow and multiplied by the enthalpy rise in the evaporator, it gives the actual cooling capacity, and dividing that by the compressor input from the energy meter gives the actual COP. Comparing the refrigerant flow, as vapour volume at suction, with the compressor’s swept volume gives its volumetric efficiency.

Controls and Services

A thermostat switches the compressor off when the water reaches the set temperature, a pressostat stops it if the high or low pressure leaves its set limits, and an overload protector trips it on excess current. The float-operated inlet tap tops the tank up as cold water is drawn off. The trainer needs a floor space of 1.5 × 1.5 m, a water supply of 5 litre/min and a 230 V, 15 A stabilised AC supply with earthing; a technical manual is supplied with it.

Other Cooling Trainers, a Cut Section and a Leak Detector

Browse Refrigeration and Air Conditioning Lab within Engineering Lab Equipment for the rest of the range.

Request a Quote

Add the trainer with Add To Cart, or reach us through the contact page with the quantity and the delivery address.

Last updated: 30 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us