• +91-85699-09696

Ice Plant Trainer Manufacturer,Supplier and Exporter in India

Ice Plant Trainer

Product Code : EL-RAACL-10087
Jlab Export is a leading Ice Plant Trainer Manufacturer,and suppliers in India

Ice Plant Trainer (code EL-RAACL-10087) is a can-type ice plant for the refrigeration lab: cans of fresh water stand in a tank of circulating brine, a hermetically sealed compressor on R-12 refrigerant cools the brine, and the cold brine freezes the water in the cans. It makes 7 kg of ice in 4 hours. This brine-tank ice plant is built by JLab in Ambala, India.

Specifications

ParameterDetail
CompressorHermetically sealed, R-12 refrigerant
CondenserAir cooled, 4 row
Expansion valve0.5 TR capacity
Evaporator½ inch OD copper tube, 75 ft long
Filter-drierSilica gel filled, 3/8 inch flare connections
Main tank600 × 375 mm, 6.5 inch expanded polystyrene insulation
Ice making7 kg total ice can capacity; 7 kg in 4 hours
Brine stirrerMotor-driven fan, single phase, 1/10 HP, 1440 rpm
InstrumentsDigital temperature indicator 0–300 °C, 1 °C least count, Cr/Al thermocouples; single-phase compressor energy meter, 10–20 A; pressure gauges 0–21 and −1 to 10.6 kg/cm², 65 mm dial; digital thermometer; HP/LP cutout and thermostat, both auto reset
ServicesFloor area 2 × 1.5 m, 1.5 m high; 220 V, 15 A single-phase stabilised supply
Quality checkEach trainer is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-RAACL-10087
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

From Brine Tank to Ice Can

The compressor raises the pressure of the refrigerant vapour and sends it to the 4-row air-cooled condenser, where it gives up heat and liquefies. After the filter-drier, the expansion valve drops the pressure, and the liquid boils inside the 75 ft copper evaporator coil in the main tank, taking heat from the brine. The motor-driven stirrer keeps the brine moving past the coil and the cans. Brine is used because it stays liquid below 0 °C.

Readings for the COP Test

Thermocouples on the digital indicator give temperatures around the circuit and the two gauges give the high and low side pressures, so the cycle can be drawn on a pressure–enthalpy chart. The refrigerating effect is the heat taken up in the evaporator, which can be cross-checked from the mass of ice made; dividing it by the compressor work from the energy meter gives the actual COP, for comparison with the theoretical value from the chart. The HP/LP cutout stops the compressor if a pressure goes out of range, and a technical manual comes with the unit.

Other Refrigeration Trainers and a Charging Unit

More cycle trainers are in Refrigeration and Air Conditioning Lab, part of Engineering Lab Equipment.

Request a Quote

Send your order through Add To Cart or the contact page, with the number of trainers and the delivery address.

Last updated: 30 October 2026


   