Apparatus for Isolated Uterus and Intestine Manufacturer,Supplier and Exporter in India
Product Code : EL-PI-2467
Jlab Export is a leading Apparatus for Isolated Uterus and Intestine Manufacturer,and suppliers in India
Smooth muscle from the uterus or a length of intestine can be kept working outside the body in this bath assembly. The tissue hangs in an organ tube of warmed, aerated salt solution, and a frontal lever writes its contractions on a kymograph. An immersion heater under thermostat control holds the bath temperature. The set comes with a teak base board or acrylic sheet, uprights, oxygen tube and capillary tubing.
Specifications
| Tissues | Isolated uterus and intestine |
| Base | Teak base board or acrylic sheet |
| Bath | Bath with organ tube for the tissue |
| Heating | Immersion heater controlled by a thermostat |
| Fittings | Uprights, organ tube, oxygen tube and capillary tubing |
| Recording | Frontal lever |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Isolated Uterus and Intestine Practicals
In pharmacy and medical college practicals, students record a dose-response curve of an agonist on the isolated tissue. Acetylcholine or histamine is used on intestine and oxytocin on uterus. Each contraction is written by the frontal lever on a Student Electrical Kymographs drum. Repeating the curve with a blocker such as atropine in the bath shows the parallel shift of competitive antagonism.
Bioassay exercises compare an unknown solution with a standard by matching or bracketing the responses. For long sessions, a Brodie Starling Kymograph takes a longer loop of paper. Institutions run these animal experiments under the approval of their animal ethics committee, and many courses now pair them with computer simulations.
Frequently Asked Questions
Which physiological salt solution goes in the bath?
The choice follows the tissue and the course manual. Tyrode solution is widely used for intestine and De Jalon solution for uterus. The immersion heater warms the solution, and air or oxygen is bubbled through it from the oxygen tube.
Why is the bath bubbled with air or oxygen?
An isolated tissue has no blood supply, so it takes its oxygen from the solution around it. A steady stream of fine bubbles keeps it supplied and mixes each added drug through the organ tube. Too fast a stream shakes the lever and spoils the trace.
What does the frontal lever do?
It is a light writing lever joined to the tissue by a thread. Each contraction lifts the lever, which magnifies the movement and writes it on the moving kymograph drum. The height of the trace shows the size of the response.
How is a dose-response curve recorded?
The agonist is added to the bath in rising doses, with the tissue washed and rested between doses. The height of each contraction is measured from the trace, and plotting response against log dose gives the familiar S-shaped curve.
Why does the baseline drift during a practical?
Drift usually comes from a thread that is too slack or too tight, a bath still settling to its set temperature, or bubbles striking the tissue. Let the thermostat settle before mounting, adjust the load so the lever sits level, and keep the bubbles gentle.
More Isolated Tissue Baths
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 20 November 2026
