Blood Bank Monitor Manufacturer,Supplier and Exporter in India
Product Code : EL-BBM-2314
Jlab Export is a leading Blood Bank Monitor Manufacturer,and suppliers in India
During a donation, this blood bank monitor watches the flow into the bag and stops the collection at the volume set by the operator. One screen shows the set volume, the volume collected, whether the flow is normal, high or low, and the time taken. A clamp then closes the tube automatically or by hand. Model A has a large LCD, while model B has a large VFD and 8 hours of battery backup.
Specifications
| Models | A and B |
| Readability | 1 ml (both models) |
| Display | Large LCD (A), large VFD (B) |
| Display shows | Set volume, volume in the bag, flow as normal, high or low, collection time |
| Alarm | Audio-visual, for high and low blood flow |
| Clamp | Closes automatically or by hand at the set volume |
| Pause | Stops collection while agitation continues |
| Input voltage | 90–270 V AC (SMPS) |
| Battery backup | None (A), 8 hours (B) |
| Calibration | Auto |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises with Practice Bags
MLT students check the volume readout first. They pour a known amount of water from a Measuring Cylinder into a practice bag on the monitor. They compare it with the figure on the screen, which reads in 1 ml steps.
A mock donation follows at a Donor Couch, with water fed into the bag from a raised container. Students set a target volume and let the clamp close by itself. On a second run they close it by hand before the target. On model B they pull the mains plug mid-run and check that the display stays on.
Frequently Asked Questions
Why does the bag keep rocking during a pause?
Blood must keep mixing with the anticoagulant already in the bag. The pause stops the collection for a moment, but the agitation carries on so the blood in the bag does not stand still and start to clot.
Should I choose model A or model B?
Both read to 1 ml, run on 90–270 V AC and calibrate automatically. Model A has a large LCD and no battery. Model B has a large VFD and 8 hours of battery backup, so it suits sites with power cuts or donation camps.
When is the clamp closed by hand?
The clamp normally closes by itself at the set volume. Manual closing lets trained staff end a collection early when they decide to, following the blood bank procedure.
What can set off a high-flow alarm?
The monitor judges flow by how fast the volume in the bag rises. A knock on the bag or someone leaning on the unit can look like a sudden surge. Keep hands clear of the bag and let trained staff check the line.
How is the monitor cleaned after a session?
Switch it off, wipe the bag holder and the case with a cloth lightly dampened with a mild disinfectant, and dry it. Any blood spill is cleaned up at once, before it dries on the unit.
Other Blood Collection Equipment
For a quote, use Add To Cart or send us a message through the contact page.