• +91-85699-09696

Boiling Heat Transfer Unit Manufacturer,Supplier and Exporter in India

Boiling Heat Transfer Unit

Product Code : EL-MLE-13270
Jlab Export is a leading Boiling Heat Transfer Unit Manufacturer,and suppliers in India

Boiling Heat Transfer Unit (code EL-MLE-13270) is a demonstration unit that makes boiling and evaporation visible inside a transparent pressure vessel filled with R1233zd refrigerant. A heating element of up to 300 W boils the liquid, and a coiled copper tube carrying cooling water condenses the vapour, so the process runs continuously in the closed vessel. In Ambala, India, JLab builds the complete boiling unit.

Specifications

ParameterDetail
Pressure vesselTransparent, 2850 mL
Tank pressure0–4 bar abs.
Heater power0–300 W
CondenserCoiled copper tube
Cooling water flow0.05–1.8 L/min
RefrigerantR1233zd, 1.2 kg fill; GWP 1; CO2-equivalent 0 t
ProtectionSafety valve 4 bar; adjustable pressure switch
InstrumentationPressure, flow rate and temperature sensors with digital display
Dimensions (L × W × H)1000 × 550 × 800 mm
WeightApprox. 65 kg
Quality checkEach boiling unit is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-MLE-13270
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

From Convection to Nucleate Boiling

At low heater power, heat passes from the element into the liquid by natural convection and no bubbles form on it. As the power rises, vapour bubbles start at points on the heating surface and leave it in growing numbers: this is nucleate boiling, in which the heat flux climbs steeply for a small rise in surface temperature. The pressure, temperature and flow sensors show each operating point on the digital display, so the onset of boiling can be matched to the heater power.

Condensation, Pressure and Cooling Water

The vapour condenses on the cooled copper coil and drips back, so the vessel pressure settles where heater power and cooling balance; raising the cooling water flow lowers the pressure and with it the boiling temperature. Water comes from the lab supply or from a separate water chiller that keeps it at 16 °C or below, and a 4 bar safety valve with an adjustable pressure switch protects the vessel against overpressure.

Other Boiling and Condensation Apparatus

The unit is listed in Mechatronics Lab Equipments, part of Mechanical Engineering Lab Equipment.

Request a Quote

Add the unit with Add To Cart, or send the quantity, whether you need a water chiller and the delivery address through our contact page.

Last updated: 30 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us