Critical Heat Flux Apparatus

Product Code : EL-HTL-10050
Jlab Export is a leading Critical Heat Flux Apparatus Manufacturer,and suppliers in India

Critical Heat Flux Apparatus (code EL-HTL-10050) is a pool boiling demonstration in which a current-heated test wire, 35 or 40 gauge and 10 cm long, sits in a glass trough of water kept at constant temperature. Raising the wire voltage step by step shows each boiling regime up to burnout. This boiling-curve apparatus is built by JLab in Ambala, India, and comes with a technical manual.

Specifications

ParameterDetail
Test wire35 gauge or 40 gauge, length 10 cm
Water heaterNichrome heater, 1 kW (1 no.)
Water vesselGlass trough
LightingTable light to observe the test wire
Wire input measurementVoltmeter and ammeter
Wire voltage controlDimmerstat
Electrical supply220 V, stabilised single phase
Floor space1 m x 1 m at working height
DocumentationTechnical manual
Quality checkEach heat flux apparatus is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-HTL-10050
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Boiling Regimes Seen on the Wire

The 1 kW nichrome heater brings the trough water up to temperature and holds it there. At low wire input, heat leaves by natural convection and no bubbles form. As the dimmerstat raises the voltage, isolated bubbles appear at nucleation sites, then merge into columns as nucleate boiling grows, and the heat flux climbs steeply for a small rise in wire temperature. At the peak of the boiling curve, the critical heat flux, vapour cannot leave fast enough for liquid to keep wetting the surface. The input fixes the heat flux of an electrically heated wire, so past that peak a vapour film blankets it, its temperature jumps towards the film boiling branch, and the thin wire glows and burns out.

Working Out the Burnout Heat Flux

The voltmeter and ammeter give the wire power, P = V × I, at the last reading before failure. Dividing by the wire surface area π d L, with d from the wire gauge and L = 10 cm, gives the critical heat flux q = V I / (π d L) in W/m². Repeating the run on the other gauge shows how wire diameter shifts the burnout flux, and the result can be compared with Zuber’s prediction for pool boiling. Each run needs a fresh length of wire.

Other Boiling and Condensation Rigs

More phase-change and conduction rigs are listed in Heat Transfer Lab, part of Engineering Lab Equipment.

Request a Quote

Use Add To Cart or the contact page to ask for a quotation, stating the number of rigs, the wire gauge you prefer and the delivery address.

Last updated: 30 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us