Heat Transfer in Agitated Vessel Manufacturer,Supplier and Exporter in India
Product Code : EL-HTL-10048
Jlab Export is a leading Heat Transfer in Agitated Vessel Manufacturer,and suppliers in India
Heat Transfer in Agitated Vessel (code EL-HTL-10048) is a stirred-vessel rig in which water in an insulated vessel of about 20 litres, heated by an electric heater at the bottom, gives up heat to cold water circulating through a helical copper coil. A motorised agitator at the centre of the coil stirs the vessel, so the heat transfer coefficient can be measured at different agitator speeds. This stirred-vessel unit is manufactured by JLab in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Vessel | About 20 litres; glass wool insulation all around; electric heater at the bottom |
| Agitator | 150 mm diameter, driven by a 1/8 HP motor, at the centre of the coil |
| Coil | Helical, 8 turns of 3/8 in copper tube |
| Controllers | For the heater and the agitator motor |
| Temperature indication | Vessel water; circulated water at inlet and outlet |
| Electricity | Single phase 230 V, 15 A, stabilised |
| Cooling water | 4–5 L/min, with a drain |
| Floor area | 1.5 m x 1 m x 1 m height |
| Quality check | Each agitated vessel unit is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-HTL-10048 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Overall Coefficient of the Coil
The heat taken up in the coil is Q = ṁ cp (To − Ti), where ṁ is the mass flow of cooling water, which runs at 4–5 L/min, and Ti and To are its inlet and outlet temperatures. Because the agitator keeps the vessel water at one temperature Tv, the driving difference is the log mean, ΔTlm = (To − Ti)/ln[(Tv − Ti)/(Tv − To)], and the overall coefficient follows as U = Q/(A ΔTlm), with A the outer surface of the 8-turn coil. U combines the film on the vessel side, the copper wall and the film inside the tube.
Effect of Agitator Speed
Stirring thins the layer of slow-moving water on the outside of the coil, so the vessel-side film coefficient, and with it U, rises as the controller raises the agitator speed. Repeating the test at several speeds gives the curve of U against speed. Vessel-side coefficients in stirred tanks are usually correlated against an agitator Reynolds number, ρND²/μ, built from the 150 mm agitator diameter D and its speed N.
Other Liquid Heat Transfer Rigs
- Unsteady State Heat Transfer Unit — test cylinder heated in a water bath kept uniform by an agitator.
- Concentric Tube Heat Exchanger — copper inner tube in a G.I. pipe, for LMTD and effectiveness.
- Shell and Tube Heat Exchanger — cold water crossing baffled copper tubes in an SS shell, with rotameters.
Look for related units in Heat Transfer Lab, within Engineering Lab Equipment.
Request a Quote
For a quotation, place the unit in an enquiry with Add To Cart or reach JLab through the contact page, with the quantity and the delivery address.
Last updated: 30 October 2026