Larger suction lines need insulation with a wider bore, and these 1.8 m lengths are made for 14 mm and 16 mm copper pipe. The flexible tube keeps heat out of the cold line and keeps water from forming on it. It has a density of 0.08 g/cc and a thermal conductivity of 0.04 W/m°C at 10 °C, and it resists ozone, weather and chemicals.

Specifications

Inside diameter14 mm or 16 mm
Length1.8 m
Density0.08 g/cc
Thermal conductivity0.04 W/m°C at 10 °C
PropertiesFlexible, resists ozone, weather and chemicals
Minimum order quantity50 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Installation Practicals for Larger Lines

On a ducted or larger split AC trainer, students insulate a suction run made from 14 mm or 16 mm Copper Pipe. Each length is slid on before the joints are brazed, kept away from the flame, then closed up and taped once the copper is cool. Bends formed in the Copper Pipe Bender are covered by easing the tube round the curve without stretching it thin.

Lengths are cut square with a Trimming Knife. The insulated pipes, drain hose and cable are then laid in a Base And Cover duct. Teachers can ask students to compare the surface temperature of bare and insulated pipe on the running unit.

Frequently Asked Questions

Which pipes does this insulation fit?
The 14 mm bore fits 14 mm OD pipe and the 16 mm bore fits 16 mm OD pipe. Smaller pipes need the Copper Pipe Insulation with a 6 to 12 mm bore.

Can it be used on outdoor pipe runs?
The material resists ozone and weather, so it can be used on outside walls. Covering the run with a PVC pipe duct also protects it from knocks and direct sun.

How do I insulate a pipe that is already installed?
Slit the tube along its length with a sharp knife, wrap it round the pipe and seal the slit with tape. Make the cut straight and close it fully, as an open seam lets moist air reach the copper.

Does the liquid line need insulating as well?
If the expansion device sits in the outdoor unit, both lines run cold and each needs its own insulation. Check where the expansion device of the unit is fitted before deciding.

How is the insulation fitted round a tight bend?
Ease it round gently so the wall is not stretched thin on the outside of the curve. If the bend is too sharp, cut the tube at the bend, mitre the two ends and tape the joint so no copper shows. A thin spot or a gap lets the pipe sweat.