This copper tee splits one refrigeration line into two, or brings two lines together, through three connections set in a T. It is made in 6, 8, 10, 12 and 14 mm sizes for copper tube of the same outside diameter. It is the metric copper tee for brazed lines, while a brass tee with male ends is made for joints that must come apart.

Specifications

MaterialCopper
Sizes6, 8, 10, 12 and 14 mm
Minimum order quantity100 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Workshop Practice with a Copper Tee

A tee lets students take a branch off a practice line, for example to feed a second evaporator or to add a gauge point. They cut Copper Pipe to length with a Tube Cutter, ream and clean the ends, and dry-fit all three tubes before heating.

The tee is brazed on the Gas Welding Plant with a Brazing Rod, heating tube and fitting evenly so the alloy is drawn into each joint. Once cool, the branch is pressure-tested with a Nitrogen Pressure Test Kit. Teachers can set the same branch in a flare-jointed line using the brass Tee Fitting and compare the two methods.

Frequently Asked Questions

How is this tee different from the brass tee?
This one is copper, sized in millimetres and joined by brazing, so the joint is permanent. The brass tee has male ends in inch sizes and connects with threaded nuts, so it can be taken apart for service.

Can the three joints of a tee be brazed one at a time?
They can, but heat from each new joint can soften the alloy in the last one. Fit all three tubes first, then braze the joints in one heating where you can, with nitrogen flowing through the line.

Which size tee should I order?
Order by the outside diameter of the main line: 6, 8, 10, 12 or 14 mm. Measure the tube with a caliper first, because copper tube is sold in both metric and inch sizes.

What causes a leak at a brazed tee?
Usually a joint that was not clean, not hot enough for the alloy to flow all the way in, or moved before it cooled. Bubble solution on a pressurised line shows which of the three joints is at fault.