• +91-85699-09696

Digital Tele Thermometer Manufacturer,Supplier and Exporter in India

Digital Tele Thermometer

Product Code : EL-RE-2220
Jlab Export is a leading Digital Tele Thermometer Manufacturer,and suppliers in India

Built for the rabbit pyrogen test, this digital tele-thermometer reads the body temperature of six rabbits from one bench unit. Each animal carries its own rectal probe, and a rotary switch on the front panel picks the channel shown on the 3½ digit red LED display. It reads 0 to 60 °C with 0.1 °C resolution.

Specifications

Channels6, selected by a rotary switch
Range0–60 °C
Resolution0.1 °C
Sensor inputRTD (PT-100) or IC sensor
Display3½ digit, 7-segment bright red LED
Power230 V AC ±10%, 50 Hz
Size275 x 175 x 75 mm (approx.)
Weight2 kg (approx.)
AccessoriesPyrogen probes (set of 6), operation manual, dust cover
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Pharmacology Practicals with the Tele-Thermometer

In B.Pharm pharmacology and quality control practicals, students carry out the rabbit pyrogen test on a sterile injection. Rabbits housed in a Small Animal Cage are moved to restrainers and allowed to settle, and a probe goes in to the same depth in each one.

Control temperatures are read on every channel before the test solution is injected into the marginal ear vein from one of the Disposable Syringes. Students then switch through the channels at set intervals, timed with a Stopwatch, and plot each rabbit’s temperature against time. Common mistakes are disturbing the animals during readings and pushing probes in to different depths.

Frequently Asked Questions

How many rabbits can be monitored at once?
Six. The instrument has 6 channels, each with its own pyrogen probe, and the rotary switch on the front panel selects which rabbit’s temperature appears on the display.

What range and resolution does it read?
It reads 0 to 60 °C in steps of 0.1 °C on the 3½ digit LED display. A pyrogen test looks for small rises in body temperature, so the 0.1 °C step is the figure that matters most.

Which sensor does the probe use?
The input takes an RTD (PT-100) or an IC sensor. A PT-100 element is platinum wire whose resistance changes in a known way with temperature, and the meter turns that change into a reading.

How should the probes be placed and cleaned?
Insert each probe to the same depth in every rabbit and leave it in place for the whole test, so the readings can be compared. Between tests, wipe the probes clean and disinfect them as your animal house procedure directs.

What comes with the instrument?
It is supplied with a set of 6 pyrogen probes, an operation manual and a dust cover. It runs on 230 V AC at 50 Hz and weighs about 2 kg.

Other Pharmacology Lab Items

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 6 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us