• +91-85699-09696

Steam Generator Manufacturer,Supplier and Exporter in India

Steam Generator

Product Code : EL-RE-13398
Jlab Export is a leading Steam Generator Manufacturer,and suppliers in India

This steam generator is a small aluminium boiler for heat experiments that need a steady supply of steam. It holds 1 litre of water, is made of heavy gauge aluminium sheet and has a rifled nozzle for the steam outlet. It comes with a tripod stand, a sample cup with a handle and two rubber stoppers, one solid and one bored for a thermometer.

Specifications

Capacity1 litre
MaterialHeavy gauge aluminium sheet
Steam outletRifled nozzle
StoppersTwo rubber stoppers: one solid, one with a thermometer hole
Also suppliedSample cup with handle, tripod stand assembly
UseHeating by steam and a continuous steam supply
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Heat Experiments Using the Steam Generator

To find the specific heat of a solid, students heat a sample such as one of the Metal Rivets for Specific Heats in the sample cup. When its temperature stops rising in the steam, they tip it quickly into cold water in a Calorimeter, stir and note the highest temperature. Passing steam into cold water in the same calorimeter gives the latent heat of vaporisation.

Steam led from the nozzle through rubber tubing heats the rod in a Linear Expansion Apparatus. Students then measure how much the rod grows between room temperature and steam temperature. With a thermometer pushed through the bored stopper, the generator also lets a class check the upper fixed point of a thermometer.

Frequently Asked Questions

Why heat the solid in steam rather than over a flame?
Steam from water boiling in an open vessel stays at the boiling point of water, so the solid reaches one steady, known temperature. A flame heats unevenly and gives no fixed starting temperature for the calculation.

How do I know the sample has reached steam temperature?
Keep heating until a thermometer beside the sample shows the same reading for a few minutes. If the sample is moved earlier, its starting temperature is too low and the specific heat comes out wrong.

How much water should go in the boiler?
Fill it only part way, so the base is well covered and the boiling water stays well below the nozzle. Never let it boil dry, and top it up only after it has cooled.

Which stopper is used for which job?
Fit the stopper with the thermometer hole when you need to read the steam temperature, as in a fixed-point check. Fit the solid stopper when all the steam should leave through the nozzle to feed an expansion tube or a calorimeter. Keep hands clear of the nozzle.

What errors do students make in the method of mixtures?
A slow transfer lets the hot solid cool in air, and splashing loses water from the calorimeter. Others are not stirring, reading the final temperature too early and letting condensed water drip in with the solid.

Other Heat and Calorimetry Apparatus

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 6 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us