Six sensitivity levels and a two-colour LED display let this electronic leak detector show both that refrigerant is present and roughly how large the leak is. It senses CFC, HCFC and HFC refrigerants down to 1/10 oz a year. It warms up by itself in 25 seconds and draws air in with a high volume pump. Two rechargeable C-size Ni-MH cells power it.
Specifications
| Refrigerants detected | CFC, HCFC and HFC |
| Sensitivity levels | Six |
| Ultimate sensitivity | 1/10 oz per year |
| Warm-up and reset | Automatic warm-up in 25 seconds, reset function |
| Leak display | Dual-colour LED leak size display |
| Pump and light | High volume pump, blue UV LED |
| Battery | 2 x C-size 1.5 V Ni-MH, rechargeable, low battery indicator |
| Battery life | 8 hours per charge, 1000 cycles |
| Operating temperature | 32 to 125 °F (0 to 52 °C) |
| Size, weight and probe | 7 x 7 in, 1.10 lb, 15 in probe |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Leak Testing Practicals on a Test Rig
Students run the probe tip slowly along every brazed joint, flare nut and valve on the charged Refrigeration Test Rig. They begin on a high sensitivity level to find the area of a leak, then step down the levels to close in on it. A spray of Bubble Solution For Leak Detection on the suspect joint confirms the exact spot.
A second exercise compares two methods on one joint. Fluorescent dye is added to the system with the Refillable Universal Oil/Dye Injector, and the blue UV LED makes the dye glow where it escapes. Teachers can slacken a flare nut slightly so the class sees the LED display climb as the probe comes closer.
Frequently Asked Questions
How should the six sensitivity levels be used?
Start on a high level to pick up the general area of a leak. Step down one level at a time as the alarm grows stronger. On the lowest levels only gas right at the leak sets off the display, which points to the faulty joint.
Why must the probe move slowly?
The sensor needs a moment to react to the air the pump draws in. Keep the tip close to the joint and move it slowly. Search below joints too, since these refrigerants are heavier than air and sink.
Can it find leaks in a system filled with nitrogen?
No. It senses CFC, HCFC and HFC refrigerants, not nitrogen. During a nitrogen pressure test, check the joints with bubble solution, or add a trace of refrigerant to the nitrogen where local rules allow it.
What does the reset function do?
Reset takes the air around the probe at that moment as the new zero. Use it when refrigerant has built up in the room, so the detector reacts only to a stronger source, which is the leak itself.
How long does a charge last?
The two C-size Ni-MH cells run the detector for about 8 hours per charge and are rated for 1000 charge cycles. A low battery indicator warns you before the cells run flat.
Other Leak Testing and Service Tools