Compressor Analyzer Manufacturer,Supplier and Exporter in India

Compressor Analyzer

Product Code : EL-WEAWLM-8735
Jlab Export is a leading Compressor Analyzer Manufacturer,and suppliers in India

A compressor analyzer lets a refrigeration technician start, run and test a single phase hermetic compressor away from its normal wiring. This one handles compressors up to 5 HP on 110, 220 or 277 V. It checks windings for opens, continuity and grounds, and a built-in 200 microfarad start capacitor helps jump-start a compressor that has locked up.

Specifications

Compressors testedSingle phase, up to 5 HP
Compressor supply voltages110, 220 or 277 V
Motor typesSplit-phase, capacitor start, PSC
Built-in start capacitor200 µF
Running current ranges0–10 A and 0–50 A
Start and run voltage ranges0–150 V and 0–600 V AC
Winding testsOpens, continuity and grounds
Capacitor and relay testsBy substitution
Protection30 A breaker
Supplied with220 V adapter cord, capacitor leads
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Compressor Fault-Finding Practicals

In a refrigeration and air conditioning lab, students first find the common, start and run terminals of a hermetic unit such as the domestic Compressor. They read the resistance between each pair of pins with a Digital Multimeter. Common to start reads higher than common to run, and start to run equals the two added together.

Next they connect the analyzer, start the compressor in its own mode and note the running current on the ammeter. A Digital Clamp Meter on the supply lead gives a second reading to compare. If the compressor runs on the analyzer but not in the system, the fault lies in its starting parts. Check the start capacitor and the Compressor Start Relay first.

Frequently Asked Questions

How does it free a locked compressor?
A compressor that is stuck mechanically will often break free when its motor is driven backwards for a moment and then started forwards. The analyzer reverses the motor rotation for this, and its 200 microfarad start capacitor gives extra starting torque.

Can it test start and run capacitors?
Yes, by substitution. The analyzer start capacitor, or an external run capacitor connected to it, takes the place of the system part. If the compressor then starts and runs normally, the original capacitor or relay is the faulty part.

Which compressors can it handle?
Single phase compressors up to 5 HP on 110, 220 or 277 V, with split-phase, capacitor start or permanent split capacitor (PSC) motors. Each type is started and run the way it was built to operate. Three phase compressors are outside its scope.

Why is the running current worth measuring?
Compared with the rated load amps on the compressor plate, it shows how hard the compressor is working. High current can point to a tight compressor or high head pressure, and low current to a short charge or worn valves. The meter reads on 0–10 A and 0–50 A ranges.

What protects the analyzer during starting?
A 30 A breaker protects it, sized so the high current of a compressor start can pass. Isolate the system supply before fitting the leads, and discharge any capacitor before handling it.