Arc Welding Transformer Manufacturer,Supplier and Exporter in India
Product Code : EL-WEAWLM-8721
Jlab Export is a leading Arc Welding Transformer Manufacturer,and suppliers in India
An arc welding transformer steps the mains supply down to a low voltage, high current AC output for stick welding with coated electrodes. This moving coil, air cooled set comes in 150 A and 200 A models, both with a 60% duty cycle. It welds with very low spatter, needs little maintenance and has an open circuit voltage of 70/80/100 V.
Specifications
| Process | AC manual metal arc (stick) welding |
| Design | Moving coil, air cooled |
| Open circuit voltage | 70/80/100 V |
| Models | 150 A and 200 A |
| Welding current range | 75–150 A (150 A model), 50–200 A (200 A model) |
| Supply | 230 V, 1 phase (150 A model), 230/400 V, 1/2 phase (200 A model) |
| Duty cycle | 60% (both models) |
| Electrode size | 12–10 SWG (150 A model), 12–8 SWG (200 A model) |
| Dimensions (L x W x H) | 22 x 11 x 13 in (150 A model), 25 x 14 x 18 in (200 A model) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Arc Welding Practicals for ITI Students
Students start by striking an arc on scrap plate, scratching or tapping the electrode, and then run straight beads at three current settings. Comparing the beads shows how current changes penetration and bead shape. Coated electrodes such as the Electrode packs are used, and each bead is cleaned with a Chipping Hammer before the next run.
Joint practice follows, with square butt, lap and T fillet joints on mild steel plate and each student behind a Welding Shield. Teachers can also explain how a moving coil set controls current: moving the coils apart increases magnetic leakage and lowers the welding current.
Frequently Asked Questions
How long can it weld before it needs a rest?
Both models are rated at 60% duty cycle. At rated current that allows about six minutes of arc time in every ten, and the air-cooled windings recover during the other four. Lower currents allow longer runs.
Should I choose the 150 A or the 200 A model?
The 150 A model runs on a 230 V single phase supply and covers 75–150 A for 12–10 SWG electrodes. The 200 A model works on 230 V or 400 V, single or two phase. It gives 50–200 A and takes electrodes up to 8 SWG for thicker work.
How is the current set on a moving coil transformer?
The gap between the primary and secondary coils is changed. Moving them apart increases magnetic leakage, which lowers the current, and moving them together raises it. The setting is chosen to suit the electrode size and plate thickness.
Why does the open circuit voltage matter?
Open circuit voltage is the voltage across the electrode holder and earth clamp before the arc is struck. A higher figure makes the arc easier to strike and steadier on AC, which helps with some electrodes. This set has an OCV of 70/80/100 V.
Can every electrode be used on an AC transformer?
No. An AC set suits the rutile rods used for most general work, but some basic low hydrogen grades need DC to run a stable arc. The electrode packet states the current type.
Other Arc Welding Sets
- Arc Welding Machine (heavy AC stick welding set)
- Portable Arc Welding Machine (DC inverter)
- Shielded Metal Arc Welding Machine
- Manual Metal Arc Welding Machine
For a quote, use Add To Cart or send us a message through the contact page.