• +91-85699-09696

Fume Hood Manufacturer,Supplier and Exporter in India

Fume Hood

Product Code : EL-ELA-5498
Jlab Export is a leading Fume Hood Manufacturer,and suppliers in India

Fume Hood (code EL-ELA-5498) is a fume cupboard that contains and exhausts toxic or otherwise harmful gases, vapours and mists from chemistry and research work. An inbuilt centrifugal blower keeps the chamber under negative pressure, and the hood has fluorescent lighting, internal electric plugs, gas, vacuum and air connections and a counterbalanced sliding sash. It is made by Jain Laboratory Instruments Pvt Ltd (JLab) at its works in Ambala, India.

Specifications

ParameterDetail
TypeLaboratory fume hood (fume exhaust hood)
PurposeContains and exhausts toxic, obnoxious or otherwise harmful gases, vapours and mists
BlowerInbuilt, motor-driven centrifugal blower unit
AirflowNegative pressure in the chamber; contaminated air is extracted from the work area and expelled to the atmosphere, with laboratory air drawn in to sweep out the work chamber
LightingFluorescent tubes with safety electrical fittings
Electric pointsInternally located electric plugs
Service connectionsGas, vacuum and air connections
Front sashCounterbalanced sliding up-down front sash (door)
Quality checkEach fume hood is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity10 units
Dispatch timeUsually 7–10 working days
Product codeEL-ELA-5498
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

How Does It Compare with Other JLab Fume Hoods?

ModelListed construction and sizesListed services and options
This fume hood (EL-ELA-5498)Inbuilt centrifugal blower; counterbalanced sliding front sashFluorescent lighting; internal electric plugs; gas, vacuum and air connections
Fume Hood Deluxe ModelWorking sizes from 4 x 2 x 2 ft to 8 x 3 x 3 ftOptional exhaust system, PVC fume duct, storage compartments and FRP or stainless steel lining
Junior Fume HoodsCombined single and double wall construction; counterbalanced tempered glass sash; shipped unassembled, without worktopWater, gas and electrical service fixtures
Fume Hood (150–160 cm wide)Width 150–160 cm, depth 60–80 cm; 28 in vertical sashInbuilt centrifugal blower; electrical services on right or left side

Choose this fume hood when you want the blower, lighting, electric points and gas, vacuum and air connections built into one unit. The deluxe model is listed in several working sizes with optional ducting and linings, the junior hood ships unassembled for fitting on your own worktop, and the 150–160 cm model gives its width and sash height.

What Is the Fume Hood Used For?

Many routine practicals release fumes that should not be breathed: concentrated acids and ammonia, hydrogen sulphide in salt analysis, organic solvents and the gases from heating or digesting samples. Inside the hood, the blower holds the chamber at a lower pressure than the room, so air flows in through the sash opening, sweeps across the work surface and carries the contaminated air out to the atmosphere instead of into the laboratory. A counterbalanced sash can be raised for setting up apparatus and lowered to narrow the opening during work.

Fume hoods are standard in senior-school chemistry laboratories, where class 11 and class 12 qualitative analysis is carried out, and in college and university chemistry, biochemistry, pharmacy and research laboratories, as well as testing and quality-control labs.

What to Specify When Ordering

  • Quantity — the minimum order is 10 units.
  • Working size and site details — the space available and where the exhaust will be ducted outside.
  • Services — which gas, vacuum, air and electrical points you need at the hood.
  • Related items — exhaust blowers, a fume scrubber or safety goggles can be quoted on the same enquiry.

Frequently Asked Questions

What does a fume hood do?
It contains and exhausts toxic, obnoxious or otherwise harmful gases, vapours and mists from the work chamber, so they are carried outside rather than into the laboratory.

How does this fume hood extract the fumes?
A motor-driven centrifugal blower creates negative pressure inside the chamber. Laboratory air is drawn in to sweep out the work chamber, and the contaminated air is expelled to the atmosphere.

Which services are built in?
Fluorescent tube lighting with safety electrical fittings, internally located electric plugs, and gas, vacuum and air connections.

What kind of front sash does it have?
A counterbalanced sliding front sash that moves up and down, so it stays where it is set.

How does it differ from the Fume Hood Deluxe Model?
The deluxe model is listed by working size, from 4 x 2 x 2 ft to 8 x 3 x 3 ft, with optional exhaust system, PVC duct, storage compartments and FRP or stainless steel lining. This hood is described by its built-in blower, lighting, electric plugs and gas, vacuum and air connections.

What should an export enquiry include?
The quantity, destination country and port or city, delivery terms such as FOB or CIF, any packing or labelling needs and the tender reference if applicable.

Who manufactures this fume hood?
Jain Laboratory Instruments Pvt Ltd (JLab) makes it at its works in Ambala, Haryana, India.

OEM Manufacturer

JLab is the trading name of Jain Laboratory Instruments Pvt Ltd, a manufacturer of laboratory apparatus and equipment in India, incorporated in 2017 and based on Hargolal Road, Ambala, Haryana. The fume hood is built at JLab’s own works rather than bought from a trader, so schools, colleges, dealers and importers buy it factory-direct, each unit is visually inspected before dispatch, and repeat orders are handled by the manufacturer. JLab exports worldwide and ships to buyers in every region — for example Taiwan in East Asia, Myanmar in Southeast Asia, Bulgaria in Eastern Europe, Bhutan in South Asia and the USA in North America. Tender information is on the JLab lab tenders page.

Fume Extraction and Lab Safety Items

  • Fume Hood Deluxe Model — a fume hood listed in five working sizes with optional ducting and linings.
  • Junior Fume Hoods — a hood with a tempered glass sash, shipped unassembled for fitting on an existing worktop.
  • Exhaust Blowers — polypropylene centrifugal blowers built for corrosive fume hood applications.
  • Fume Scrubber — a polypropylene gas/liquid scrubber for acid and base laden fume streams.
  • Safety Goggles — impact- and splash-resistant eye protection for bench work.

See the full Laboratory Fume Hoods range, or browse Educational Laboratory Apparatus and Laboratory Apparatus.

Request a Quote

Ask for a quotation with the Add To Cart enquiry button on this page or through the contact page, giving the number of hoods, the services you need and the delivery destination.

Last updated: 15 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us