• +91-85699-09696

Energy Loss in Pipe System Manufacturer,Supplier and Exporter in India

Energy Loss in Pipe System

Product Code : EL-MLE-13254
Jlab Export is a leading Energy Loss in Pipe System Manufacturer,and suppliers in India

Energy Loss in Pipe System (code EL-MLE-13254) is a pipe-flow rig, model JL108/02, for investigating pressure losses in piping elements and shut-off devices and for measuring flow rate by the differential pressure method. Six pipe sections that can each be shut off carry a sudden contraction and enlargement, Y-pieces, T-pieces, corners and bends. JLab builds the energy-loss pipe rig in Ambala, India.

Specifications

ParameterDetail
ModelJL108/02
Pipe sectionsSix, individually shut-off, with sudden contraction, sudden enlargement, Y-pieces, T-pieces, corners and bends
Interchangeable sectionOne pipe section holding shut-off or measuring objects
Measuring objectsVenturi nozzle, orifice plate flow meter, measuring nozzle (transparent)
Shut-off devicesAngle seat valve, gate valve
Pressure measurementAnnular chambers; 2 twin tube manometers for pressure difference
Flow rate and water supplyFlow rate from the base module; water from the base module or a laboratory supply
AccessoriesAll accessories included
Quality checkEach pipe rig is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-MLE-13254
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Working Out Loss Coefficients

Each element is tested by reading the pressure difference across it on a twin tube manometer at a known flow rate. The head loss h = Δp/ρg is then written as a multiple of the velocity head, h = K v²/2g, which gives the loss coefficient K of the bend, corner, branch or valve. Darcy-Weisbach uses the same velocity-head form for friction along a straight pipe, h = f (L/D) v²/2g, so fitting losses can be added to pipe friction when a whole system is assessed. The sudden enlargement and contraction show how abrupt changes of section raise the loss, and the angle seat and gate valves can be compared at the same flow rate.

Flow Measurement by Differential Pressure

The Venturi nozzle, orifice plate and measuring nozzle all narrow the flow and create a pressure drop that rises with the square of the flow rate. Fitting them in turn in the interchangeable section and checking them against the base module flow rate gives each meter’s discharge coefficient, and shows that the orifice plate loses more of its pressure drop for good than the Venturi nozzle does.

Other Pipe Loss and Flow Meter Apparatus

Pipe-flow rigs like this one appear in Mechatronics Lab Equipments under Mechanical Engineering Lab Equipment.

Request a Quote

Use Add To Cart or the contact page for a quotation; state model JL108/02, the quantity and your delivery address.

Last updated: 30 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us