• +91-85699-09696

Karman Cannula Manufacturer,Supplier and Exporter in India

Karman Cannula

Product Code : EL-HRG-3763
Jlab Export is a leading Karman Cannula Manufacturer,and suppliers in India

A Karman cannula is a slim flexible cannula that trained clinicians connect to an aspiration syringe or suction apparatus in gynaecological procedures. This one has a smooth surface, a rounded tip and smooth-edged eyes close to the tip. A universal connector at the other end fits suction apparatus. It is made in sizes from 4 mm to 12 mm.

Specifications

SurfaceSmooth
TipRounded
EyesOne or two smooth-edged eyes near the tip
ConnectorUniversal, for suction apparatus
Sizes4 mm to 12 mm
Minimum order quantity50 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Skills Lab Exercises for Nursing Students

Nursing and theatre-technician students learn to set out a procedure tray before any clinical posting. A typical exercise gives them mixed cannula sizes, a Kidney Tray and a list, and asks them to pick the sizes named and lay them out in order from small to large.

A second exercise works on the equipment only. Students join the universal connector to a length of Suction Tube on a training suction unit. They switch it on, close the tip with a gloved finger and watch the gauge hold, then look for cracks, kinks and rough eye edges. Wearing Examination Gloves for this keeps the habit the ward will expect.

Frequently Asked Questions

How are the cannula sizes told apart?
The size, from 4 mm to 12 mm, is the outside diameter of the tube. Sizes look alike at a glance, so store each one in its own labelled box or tray section and check the label before it goes on a tray.

Will the connector fit our aspirator or suction unit?
The universal connector is made to join suction apparatus and its tubing. Some hand aspirators take a cannula only through an adapter, so try one cannula on your own unit and check the joint holds without leaking air before ordering in bulk.

Can the cannula be cleaned and used again?
Reprocessing follows the instructions on the pack and the infection-control policy of the hospital. Do not boil or autoclave a flexible cannula unless that is allowed, because heat can soften or bend it and spoil the eyes.

What should be checked before a cannula goes on a tray?
Look along its length for cracks, kinks or flattened sections, run a finger over the tip and eye edges for roughness, and check the connector is firm. Any cannula that fails is set aside and not used.

Other Hospital Tubes and Catheters

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 13 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us