• +91-85699-09696

LPG Cylinder Regulator Manufacturer,Supplier and Exporter in India

LPG Cylinder Regulator

Product Code : EL-AELE-12921
Jlab Export is a leading LPG Cylinder Regulator Manufacturer,and suppliers in India

A cylinder regulator brings the pressure of bottled gas down to a steady, low level that a burner can use. This one clips onto butane cylinders with a 21 mm clip-on valve and delivers gas at 80–90 mbar. Its hose nozzle takes standard 8 mm hose, and it passes up to 1.5 kg of gas an hour.

Specifications

Fits Butane cylinders with a 21 mm clip-on valve
Hose nozzle For standard 8 mm hose
Maximum flow 1.5 kg/hr
Operating pressure 80–90 mbar
Minimum order quantity 10 units
Dispatch time Usually 4–6 working days
Manufacturer JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Practicals with Lab Gas Burners

Setting up a gas point is a useful first lesson. Students press the regulator onto the valve of an LPG Cylinder until it clicks, then push LPG Hose fully onto the nozzle. With a clip on each end, the hose goes to a Bunsen Burner, and each joint is tested with soapy water.

A simple measuring exercise uses the flow figure. Students weigh the cylinder before and after a timed heating run and work out the gas used per hour. They then compare it with the 1.5 kg/hr the regulator can deliver.

Frequently Asked Questions

Why is the burner flame low when the cylinder still has gas?
Check that the regulator is clicked fully home and that the hose is not kinked or squashed. A blocked burner jet gives the same sign, and butane gives off gas slowly in a cold room. If a full cylinder still gives a low flame, change the regulator.

What hose does it take?
Standard 8 mm bore hose, pushed fully over the nozzle and held with a hose clip. The LPG Hose has an 8 mm inner diameter for this job.

What do 80–90 mbar and 1.5 kg/hr mean?
The first is the outlet pressure: the steady, low pressure fed to the burner whatever the pressure in the cylinder. The second is the most gas the regulator can pass in an hour, so add up the burners on the line and stay under it.

How do I fit and remove it safely?
Fit it with no flame nearby, pressing it squarely onto the valve until it clicks. Remove it only after the burner is out and the gas is off, so no gas escapes from the hose.

When should the regulator be replaced?
Replace it if the body is cracked, the seal at the valve leaks, or the flame keeps changing size at a steady setting. Change the hose at the same time if it has hardened or cracked.

Other LPG and Burner Items

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 5 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us