Pneumatic Trainer Basic Manufacturer,Supplier and Exporter in India
Product Code : EL-TL-10065
Jlab Export is a leading Pneumatic Trainer Basic Manufacturer,and suppliers in India
Pneumatic Trainer Basic (code EL-TL-10065) is a mobile, self-contained compressed-air trainer for a set course of experiments, from running a single-acting cylinder to sequencing a pneumatic motor with a double-acting cylinder. Industrial components and circuits are used throughout, components can be fitted at any corner of its modular frame, and specially designed quick couplings speed up connections. JLab manufactures this pneumatic trainer in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Actuators | Single-acting and double-acting cylinders; pneumatic motor |
| Directional control valves | 5/3 way lever operated; 5/2 way single solenoid |
| Speed control | Flow control, meter-in and meter-out |
| Logic | AND gate |
| Frame | Modular; components fit at any corner |
| Connections | Specially designed quick couplings |
| Unit | Mobile, self-contained |
| Quality check | Each trainer is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-TL-10065 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Experiments on the Basic Trainer
Work starts with a single-acting cylinder: plain operation, speed control and an AND-gate circuit. A pneumatic motor is then run and its speed controlled. A double-acting cylinder is operated from a 5/3 way lever-operated directional control valve, and its speed is set by flow control in meter-in, meter-out and forward-and-return-stroke arrangements. Sequencing exercises pair the motor with a double-acting cylinder, and a double-acting cylinder with a single-acting one. The last two experiments switch a single-acting and a double-acting cylinder through 5/2 way single-solenoid valves.
Meter-In and Meter-Out Compared
Meter-in throttles the air entering the cylinder; meter-out throttles the air leaving it. Because air is compressible, meter-out holds the piston between supply pressure and a cushion of exhaust air, which usually gives steadier speed on a double-acting cylinder, especially when the load tends to run ahead. Trying both on the same cylinder lets students see the difference for themselves.
Other Pneumatic and Hydraulic Trainers
- Electropneumatic Training — relays, sensors, timers and a counter controlling solenoid-valve circuits.
- Transparent Pneumatic Components — cut-section direction control valves and cylinders showing internal construction.
- Hydraulic Trainer Classic — oil-hydraulic circuits on a mobile, self-contained trainer.
It is grouped in Thermodynamics Lab under Fluid Mechanics and Hydraulics Lab Equipment.
Request a Quote
Request a quotation with Add To Cart, or use the contact page to send the number of trainers and the delivery city.
Last updated: 30 October 2026