Safety and Control in Heating Systems Manufacturer,Supplier and Exporter in India

Safety and Control in Heating Systems

Product Code : JL-ELA-5448
Jlab Export is a leading Safety and Control in Heating Systems Manufacturer,and suppliers in India, Safety and Control in Heating Systems Manufacturer,and suppliers in South Africa, Safety and Control in Heating Systems Algeria (Algiers), Safety and Control in Heating Systems Angola (Luanda), Safety and Control in Heating Systems Argentina (Buenos Aires), Safety and Control in Heating Systems Armenia (Yerevan), Safety and Control in Heating Systems Australia (Canberra), Safety and Control in Heating Systems Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

Safety and Control in Heating Systems
Using the test stand various safety and control devices can be investigated and evaluated.
Typical industrial components are used.
PC data acquisition allows the data to be displayed graphically.
A supply of water and compressed air is necessary for operation.
Investigation of heating safety fittings
Demonstration of the function of safety fittings using compressed air: thermostatic valve, safety Pressure cut-out, safety valve, temperature controller, thermal discharge safety device
Demonstration of the function of safety fittings in a closed water circuit with circulating pump and expansion vessel: air separator, quick-action ventilating valve, safety valve, flow switch, pressure reducing valve
Electrical heater for thermal safety fittings: temperature controller, thermal discharge safety device.
Technical Specifiaction:-
Temperature controller: 70...100°C
Safety pressure cut-out :  1...10bar, adjustable
Safety valve: 2,4bar
Flow switch: 7,7...13,4L/min (increasing flow rate)
Pressure reducing valve: 1,5...6bar
Heater: 800W

   