Safety and Control in Heating Systems Manufacturer,Supplier and Exporter in India
Product Code : EL-ELA-5448
Jlab Export is a leading Safety and Control in Heating Systems Manufacturer,and suppliers in India
Safety and Control in Heating Systems (code EL-ELA-5448) is a test stand on which students investigate and evaluate the safety and control devices of a heating system, built from typical industrial components and linked to PC data acquisition that displays the results graphically. It combines a compressed-air section, a closed water circuit with circulating pump and expansion vessel, and an 800 W electrical heater for the thermal safety fittings. It is made by Jain Laboratory Instruments Pvt Ltd (JLab) at its works in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Type | Test stand for investigating heating safety fittings and control devices |
| Components | Typical industrial components |
| Fittings demonstrated with compressed air | Thermostatic valve, safety pressure cut-out, safety valve, temperature controller, thermal discharge safety device |
| Fittings in the closed water circuit | Air separator, quick-action ventilating valve, safety valve, flow switch, pressure reducing valve; circuit with circulating pump and expansion vessel |
| Thermal safety fittings on the electrical heater | Temperature controller, thermal discharge safety device |
| Temperature controller | 70–100 °C |
| Safety pressure cut-out | 1–10 bar, adjustable |
| Safety valve | 2.4 bar |
| Flow switch | 7.7–13.4 L/min (increasing flow rate) |
| Pressure reducing valve | 1.5–6 bar |
| Heater | 800 W, electrical |
| Data acquisition | PC data acquisition with graphical display of the data |
| Services required | Water supply and compressed air supply |
| Quality check | Each test stand is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 7–10 working days |
| Product code | EL-ELA-5448 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
How Does It Compare with the Safety Devices Training Panel?
| Trainer | Format | Heat and pressure source | Listed features |
|---|---|---|---|
| This test stand (EL-ELA-5448) | Test stand | Compressed air, a closed water circuit with pump, and an electrical heater | Wide set of safety and control fittings, specified set points, PC data acquisition with graphical display |
| Safety Devices Training Panel | Panel for a stand | Electrically heated pressure vessel filled through different pipe sections | Safety devices for a sealed water heater, thermal discharge safety device to a blow-off pipe, pressure and temperature display |
Choose this test stand when students should evaluate many fittings and record the results on a PC; the training panel is the simpler choice for showing how the safety devices of a sealed water heater trip.
What Is the Safety and Control in Heating Systems Test Stand Used For?
A hot water heating system relies on a set of fittings that each guard against one danger. The safety valve opens to release pressure above its set point, here 2.4 bar; the safety pressure cut-out switches off the heat input when pressure climbs past its adjustable limit; the thermal discharge safety device lets hot water out when the temperature limit is passed; the expansion vessel takes up the extra volume of water as it heats; and the air separator and quick-action ventilating valve remove air that would block circulation. The flow switch responds once the flow rises into its 7.7–13.4 L/min range, the pressure reducing valve brings the supply pressure down to a set level, and the temperature controller holds the water between 70 and 100 °C.
On the stand, students first see the fittings respond to compressed air, then watch them work in the closed water circuit and on the electrical heater, while the PC data acquisition displays the measured data graphically. This suits heating-engineering and building services courses at polytechnics and engineering colleges, as well as ITI and TVET plumbing and heating trades where commissioning and safety checks are taught.
What to Specify When Ordering
- Services — confirm that your lab has the water and compressed air supplies the stand needs, and state your electrical supply.
- PC and software — ask whether a computer is to be included or whether you will provide one for the data acquisition.
- Quantity — the minimum order is 10 units.
- Companion trainers — the safety devices panel and heating circuit trainers listed below.
Frequently Asked Questions
Which safety fittings can be investigated?
With compressed air: a thermostatic valve, safety pressure cut-out, safety valve, temperature controller and thermal discharge safety device. In the closed water circuit: an air separator, quick-action ventilating valve, safety valve, flow switch and pressure reducing valve. On the electrical heater: a temperature controller and thermal discharge safety device.
What are the set points and ranges?
Temperature controller 70–100 °C, safety pressure cut-out 1–10 bar adjustable, safety valve 2.4 bar, flow switch 7.7–13.4 L/min with increasing flow, pressure reducing valve 1.5–6 bar, and an 800 W heater.
How are results recorded?
Through PC data acquisition, which displays the data graphically. Confirm in your enquiry whether you need the PC supplied.
What services does the stand need?
A supply of water and compressed air is necessary for operation, along with mains power for the heater and pump.
How does it differ from the Safety Devices Training Panel?
This stand covers a broader set of safety and control fittings with PC data acquisition. The panel centres on an electrically heated pressure vessel and the safety devices that protect a sealed water heater.
What should be in an export enquiry?
Quantity, destination country and port or city, delivery terms such as FOB or CIF, site services, packing or labelling needs and any tender reference.
Who manufactures this test stand?
Jain Laboratory Instruments Pvt Ltd (JLab) builds it at its Ambala works in Haryana, India.
OEM Manufacturer
JLab is the trading name of Jain Laboratory Instruments Pvt Ltd, a manufacturer of engineering lab equipment in India, incorporated in 2017 and based on Hargolal Road, Ambala, Haryana. This heating safety test stand is built at JLab’s own works instead of being bought from a trader, so colleges, training institutes, dealers and importers get it direct from the manufacturer, every stand is visually inspected before dispatch, and spare fittings and repeat orders are handled in-house. The company is registered under CIN U29309HR2017PTC069123 and holds MSME Udyam registration UDYAM-HR-01-0003849 as a manufacturing enterprise. JLab exports worldwide and ships to buyers in every region — for example Tanzania in East Africa, Honduras in Central America and the Caribbean, Canada in North America, France in Western Europe and Tunisia in North Africa. Tender buyers can use the JLab lab tenders page.
Related Heating Safety Trainers
- Safety Devices Training Panel — safety devices for a sealed water heater on an electrically heated pressure vessel.
- Domestic Heating Circuit Training Panel — a central heating circuit with controller, mixing valve, pump and a differential pressure overflow valve.
- Oil Tank Safety Trainer — leak detection and overfill protection on a heating oil tank.
- Instantaneous Gas Heater — PLC-simulated safety functions and faults of a gas water heater.
Browse the Educational Laboratory Apparatus range or all Laboratory Apparatus.
Request a Quote
JLab quotes directly as the manufacturer. Use the Add To Cart enquiry button on this page, or send the quantity (minimum 10 units), whether a PC is needed, your site services and the delivery location through the contact page.
Last updated: 9 October 2026