• +91-85699-09696

Shortwave Medical Diathermy (Valve Type) Manufacturer,Supplier and Exporter in India

Shortwave Medical Diathermy (Valve Type)

Product Code : EL-PE-3826
Jlab Export is a leading Shortwave Medical Diathermy (Valve Type) Manufacturer,and suppliers in India

This shortwave diathermy unit is a valve-driven high-frequency generator that works at 27.12 MHz with an output of about 500 W. The set includes a pair of pad electrodes on cables, felt cloth covers, a machine cover and spare fuses. A mobile trolley carries it between treatment cubicles.

Specifications

Output power500 W (approx.)
Operating frequency27.12 MHz
Wavelength11 m
HF power sourceVacuum generating valve
Mains supply220 V, 50 Hz
Fuse5 A
Electrodes1 pair of pad electrodes with cables and felt cloth covers
Also suppliedMain cord, machine cover, 5 spare fuses, mobile trolley
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Electrotherapy Practicals with the Diathermy

In a physiotherapy college, students begin by identifying the controls and parts of the unit. These are the mains switch, the valve generator, the output and tuning controls, and the patient circuit with its two pad electrodes. A teacher can then show tuning with a test load placed between the pads. Held near the electrodes, the bulb of a Neon Tester glows brightest when the patient circuit is in resonance with the machine circuit.

With the unit switched off and unplugged, students check each electrode cable for continuity and broken insulation using a Digital Multimeter. They also look for damp patches on the felt covers and inspect the earth pin of the mains cord. Before switching on, they clear the field area of metal objects, watches and mobile phones.

Frequently Asked Questions

What does tuning mean on a shortwave diathermy?
Tuning brings the patient circuit, formed by the cables, pads and the body part between them, into resonance with the machine circuit at 27.12 MHz. Power passes to the pads well only when the two circuits are in tune, so the circuit is tuned again after the pads are moved.

Why do the pad electrodes have felt covers?
The felt keeps a gap between the rubber pad and the skin and takes up sweat. Moisture or a pad pressed hard on one spot concentrates the field and can cause a hot spot, so the covers are kept clean and dry.

Why must the two cables be kept apart?
The cables carry the high-frequency current. If they cross, touch each other or lie on a metal frame, the field gathers between them and the leads can overheat. Run them apart and clear of the trolley frame and the treatment couch.

What should be checked before each session?
Check the mains cord and earth, the insulation of both electrode cables, the pads for cracks and the felt covers for damp. Set the output to zero before switching on. Clinical use follows the hospital protocol and is carried out by trained physiotherapy staff.

What are the spare fuses for?
The mains circuit is protected by a 5 A fuse, and five spares come with the unit. Replace a fuse only with the unit unplugged and with the same rating. A fuse that blows again points to a fault for a service technician to trace.

Other Heating Equipment for Physiotherapy