Traction Machine Electronic Manufacturer,Supplier and Exporter in India
Product Code : EL-PE-3829
Jlab Export is a leading Traction Machine Electronic Manufacturer,and suppliers in India
An electronic traction machine pulls on a harness through a rope with a set force and holds it for a set time. This model gives 5 to 45 kg, and up to 90 kg through the force doubler. Hold time is chosen from 20, 40 or 60 s, the time shows on a digital display, and the unit mounts on a table or a wall.
Specifications
| Traction force | 5 to 45 kg |
| With force doubler | Up to 90 kg |
| Hold time settings | 20, 40 and 60 s |
| Time | Digital display |
| Mounting | Table or wall |
| Mains supply | 220 V, 50 Hz |
| Also supplied | Machine cover, 5 spare fuses |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises with the Traction Unit
Physiotherapy students learn the controls by running the machine with the rope hooked to a fixed point instead of a person. A Balance Spring Dial Type placed in the rope line shows the real pull, which they compare with the force set on the machine at several settings.
They then time each hold period with a Digital Stopwatch and check it against the 20, 40 and 60 s settings. A second exercise repeats the force check with the doubler fitted, to see how the pulley halves the rope travel and doubles the pull.
Frequently Asked Questions
What does the force doubler do?
The doubler is a pulley block that the rope runs through. It doubles the pull at the harness, so the 5 to 45 kg range becomes up to 90 kg. The harness then moves half as far as the rope.
Should the unit go on a table or on the wall?
Either works. The mounting decides the angle of pull, so it is placed where the rope runs in a straight line to the harness without rubbing on the couch edge. The wall or table fixing must carry the full pull.
How do we check that the pull matches the setting?
Hook a dial spring balance between the rope and a fixed anchor, set a force and read the dial during the hold. Repeat at low and high settings. If readings drift from the settings, have a service technician recalibrate the unit.
Why does the unit knock or click at higher forces?
Look first at the rope seating on its pulleys and the doubler, then check that the mounting bolts are tight. A frayed rope also jumps on the pulley. A noise that remains after these checks needs a technician before the unit is used again.
Other Physiotherapy Traction Equipment
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 13 November 2026