• +91-85699-09696

Traction Machine Electronic Manufacturer,Supplier and Exporter in India

Traction Machine Electronic

Product Code : EL-PE-3829
Jlab Export is a leading Traction Machine Electronic Manufacturer,and suppliers in India

An electronic traction machine pulls on a harness through a rope with a set force and holds it for a set time. This model gives 5 to 45 kg, and up to 90 kg through the force doubler. Hold time is chosen from 20, 40 or 60 s, the time shows on a digital display, and the unit mounts on a table or a wall.

Specifications

Traction force5 to 45 kg
With force doublerUp to 90 kg
Hold time settings20, 40 and 60 s
TimeDigital display
MountingTable or wall
Mains supply220 V, 50 Hz
Also suppliedMachine cover, 5 spare fuses
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Exercises with the Traction Unit

Physiotherapy students learn the controls by running the machine with the rope hooked to a fixed point instead of a person. A Balance Spring Dial Type placed in the rope line shows the real pull, which they compare with the force set on the machine at several settings.

They then time each hold period with a Digital Stopwatch and check it against the 20, 40 and 60 s settings. A second exercise repeats the force check with the doubler fitted, to see how the pulley halves the rope travel and doubles the pull.

Frequently Asked Questions

What does the force doubler do?
The doubler is a pulley block that the rope runs through. It doubles the pull at the harness, so the 5 to 45 kg range becomes up to 90 kg. The harness then moves half as far as the rope.

Should the unit go on a table or on the wall?
Either works. The mounting decides the angle of pull, so it is placed where the rope runs in a straight line to the harness without rubbing on the couch edge. The wall or table fixing must carry the full pull.

How do we check that the pull matches the setting?
Hook a dial spring balance between the rope and a fixed anchor, set a force and read the dial during the hold. Repeat at low and high settings. If readings drift from the settings, have a service technician recalibrate the unit.

Why does the unit knock or click at higher forces?
Look first at the rope seating on its pulleys and the doubler, then check that the mounting bolts are tight. A frayed rope also jumps on the pulley. A noise that remains after these checks needs a technician before the unit is used again.

Other Physiotherapy Traction Equipment