• +91-85699-09696

Digital & Deluxe Ultrasonic Therapy Unit Manufacturer,Supplier and Exporter in India

Digital & Deluxe Ultrasonic Therapy Unit

Product Code : EL-PE-3839
Jlab Export is a leading Digital & Deluxe Ultrasonic Therapy Unit Manufacturer,and suppliers in India

Ultrasonic therapy units drive a treatment head that sends ultrasound into the tissue through a layer of coupling gel. This unit works in continuous or pulse mode and reaches 2.5 W/cm² continuous and 3.5 W/cm² pulsed. A meter displays the output, the timer runs from 0 to 30 minutes, and it runs on 220 V mains.

Specifications

Power output2.5 W/cm² continuous, 3.5 W/cm² pulsed
Output modesContinuous and pulse
Timer0 to 30 minutes
Output displayMeter
Mains supply220 V, 50 Hz
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Practicals with the Ultrasound Head

A standard first practical is the output check. Students hold the head face up, cover the face with a thin layer of water and raise the output slowly. The water ripples and forms a fine mist when the head is working, and stays still when it is not.

They then set a short time on the timer and check it with a Digital Stopwatch, and compare the meter reading in continuous and pulse mode. With the unit unplugged, the head cable is tested for continuity with a Multimeter, Analog while being flexed near the plug and the head.

Frequently Asked Questions

How can we tell the head is giving output?
Do the water test: hold the head face up, put a thin layer of water on it and raise the output. Ripples and a fine spray show that the crystal is working. No movement at a raised setting means the head or cable needs a technician.

What is the difference between continuous and pulse mode?
In continuous mode the head sends ultrasound without a break. In pulse mode it switches on and off rapidly, so the average output is lower than the peak. This unit allows up to 2.5 W/cm² continuous and 3.5 W/cm² in pulse mode.

Why is the output given in W/cm²?
Intensity is the power from the head divided by its effective radiating area, the part of the face that actually gives out ultrasound. Two heads of different size at the same wattage give different intensities, so W/cm² is the figure that is compared.

How is the output checked during servicing?
Biomedical engineers measure ultrasound power with an ultrasound power meter, usually a radiation force balance, and check the timer and the mains safety of the unit. Plan such a check at regular intervals and after any drop or knock to the head.