TENS Machine Manufacturer,Supplier and Exporter in India

TENS Machine

Product Code : EL-PE-3838
Jlab Export is a leading TENS Machine Manufacturer,and suppliers in India

A TENS machine passes small low-voltage electrical pulses through electrodes placed on the skin. This one has two output channels, so two pairs of electrodes can be run at once, and it works in both low and high TENS modes. It is used in physiotherapy departments and in electrotherapy teaching.

Specifications

ChannelsDual channel
TENS modesLow and high
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Electrotherapy Lab Exercises

Students connect one channel to a resistor load and display the pulse train on a Dual Trace Oscilloscope. They compare the pulse rate and pulse width in low and high modes, then connect the second channel and look at both outputs side by side.

A pre-use check is practised on every lab day. With the machine off, each lead is tested with a Multimeter, Analog, and the electrodes are checked for dried gel, curled edges and loss of stickiness. Students also practise explaining the difference between TENS and interferential current.

Frequently Asked Questions

What do the low and high TENS modes mean?
High TENS, also called conventional TENS, uses a fast pulse rate at a low intensity that is felt as tingling. Low TENS uses a slow pulse rate, often at a higher intensity. The physiotherapist chooses the mode and settings for each patient.

What is the difference between TENS and IFT?
TENS sends low-frequency pulses straight through a pair of skin electrodes. Interferential therapy uses two medium-frequency currents that cross in the tissue and produce a low-frequency beat. TENS needs one pair of electrodes per channel, while 4 pole IFT uses two crossed pairs.

The machine is on but nothing is felt. What should we check?
Check that the electrodes lie flat on the skin and are not too far apart, and that the intensity is turned up on the right channel. Then test the lead wires, which can break inside the insulation, and replace electrodes that no longer stick.

When should the electrodes be replaced?
Replace self-adhesive electrodes when they stop sticking firmly, the gel dries or the edges curl. Poor contact concentrates the current on a small area. Store electrodes on their backing sheet in a sealed bag, and keep each patient on their own set.

Why does the machine have two channels?
Each channel drives its own pair of electrodes. Two channels allow two areas to be covered at once, or four electrodes to be arranged over a larger area, as the physiotherapist decides.