Digital Ultrasonic Physiotherapy Equipment Manufacturer,Supplier and Exporter in India

Digital Ultrasonic Physiotherapy Equipment

Product Code : EL-PE-3842
Jlab Export is a leading Digital Ultrasonic Physiotherapy Equipment Manufacturer,and suppliers in India

Working at 1 MHz, this digital ultrasonic physiotherapy unit drives its treatment head at a single fixed frequency. Its power output is 17 W in continuous mode, with pulsed figures of 22 W and 29 W. It runs on 220/240 V AC mains. Ultrasound passes from the head into the body only through a coupling medium such as gel or water.

Specifications

Operating frequency1 MHz
Power output17 W continuous; 22 W and 29 W pulsed
Input voltage220/240 V AC, 50 Hz
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Experiments with the 1 MHz Head

A heating experiment shows what the head does in water. Students fill a Polypropylene Beaker with water, hold the head under the surface facing down and run it at a low setting for a short, fixed time. They read the water temperature before and after with a Digital Stem Thermometer, then repeat in pulsed output and compare the rise.

Teachers also use the unit to show why the head must always be coupled. Air does not carry ultrasound, so with no water or gel the energy stays in the head. Students practise the handling routine: output at zero, head coupled, then output raised.

Frequently Asked Questions

What does the 1 MHz frequency mean in practice?
Frequency decides how deep ultrasound travels before it is absorbed. A 1 MHz head reaches deeper tissue than a 3 MHz head, which is absorbed nearer the surface. This unit has a single 1 MHz frequency, and the physiotherapist plans each treatment around it.

Why should the head never be switched on in air?
Ultrasound does not pass from the head into air, so the energy reflects back into the crystal and the head heats up. Repeated dry running can crack the crystal. Couple the head with gel or water before raising the output, and turn it to zero before lifting it off.

Which coupling gel should be used?
Use a water-based ultrasound gel free of air bubbles. Bubbles and thick or oily creams block part of the beam. Spread a thin even layer and keep the head moving in full contact. Wipe gel off the head after use with a soft damp cloth.

The unit cuts out when the head touches the skin. What should we check?
Check the gel layer first, as a dry patch or bubbles break the contact. Keep the whole face of the head flat on the skin and look at the head cable for damage near the plug. If it still cuts out, have the output checked by a service engineer.