An antibiotic zone reader measures the clear zones of inhibition that form round antibiotic cups or discs on a seeded agar plate. This reader covers zone diameters from 0 to 35 mm and reads them to 0.02 mm. Comparing the zones given by a test sample with those of a standard shows the strength of the antibiotic.

Specifications

MeasuresDiameter of the inhibited zone in a petri dish
Range0 to 35 mm
Least count0.02 mm
Power supply220 V AC, 50 Hz
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Assay Practicals with the Zone Reader

The cup-plate assay is a core practical in pharmaceutical microbiology. Students pour agar seeded with the test organism into a Petri Dish (Polypropylene) and cut wells in the set agar with a Cork Borer. Standard and test dilutions go into the wells with a Variable Volume Micropipette.

The plates are incubated in an Incubator Bacteriological, and the zone round each well is read on the reader. Students plot zone diameter against the log of the dose and find the potency of the test sample. A disc diffusion test for sensitivity of a culture to several antibiotics is read the same way.

Frequently Asked Questions

How do I read a zone with a fuzzy edge?
Read to the point where growth clearly stops, and read every zone on the plate in the same way. Tilting the plate or changing the lighting angle often makes a faint edge easier to see.

Should colonies growing inside the zone be counted?
First check that the culture is pure, since stray colonies often mean contamination, and repeat the plate if it is mixed. With a pure culture, follow the reading rule given in your assay method.

Why must the agar layer be level and even in depth?
The antibiotic spreads outward through the agar, so a thin patch gives a larger zone and a thick patch a smaller one. Pour each plate on a level surface with the same volume of medium.

How is potency worked out from the readings?
Zones from two or more doses of the standard and of the test sample are measured. Zone diameter is plotted against log dose, and the potency of the test is read from where its zones fall against the standard line.

What range and least count does this reader have?
It reads zone diameters from 0 to 35 mm to the nearest 0.02 mm. Choose doses that give zones inside that range, since larger zones cannot be read on it.