Digital Conductivity Meter Manufacturer,Supplier and Exporter in India
Product Code : EL-ELA-5299
Jlab Export is a leading Digital Conductivity Meter Manufacturer,and suppliers in India
Digital Conductivity Meter (code EL-ELA-5299) is a mains-powered bench meter with a 3½-digit LED display for measuring the electrical conductivity of solutions in chemistry, water-testing and soil labs. It covers 0 to 1000 over five ranges with an accuracy of ±1% FS ±1 digit, runs on 230 V AC and comes with an operation manual and dust cover. It is made by Jain Laboratory Instruments Pvt Ltd (JLab) at its works in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Display | 3½-digit LED |
| Measuring range | 0 to 1000, in 5 ranges (unit listed as mhos/cm — confirm the range steps with JLab) |
| Accuracy | ±1% FS ±1 digit |
| Power requirement | 230 V AC |
| Spare conductivity cells | Cell constants 1, 0.5 and 0.1 |
| Supplied with | Operation manual and dust cover |
| Quality check | Each meter is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 7–10 working days |
| Product code | EL-ELA-5299 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
How Does It Compare with Other JLab Conductivity Meters?
| Model | Ranges and accuracy | Other listed details |
|---|---|---|
| This meter (EL-ELA-5299) | 0 to 1000 in 5 ranges; ±1% FS ±1 digit | 3½-digit LED; 230 V AC; spare cells of constant 1, 0.5 and 0.1; manual and dust cover |
| Digital Conductivity Meter (laboratory and field models) | Five ranges up to 0–1000 mS/cm; ±1% FS ±1 digit | 3½-digit LED; manual temperature compensation; platinum dip-type cell; 230 V AC |
| Digital Conductivity Meter (microcontroller model) | Automatic range selection; ±0.5% FS ±1 digit | Automatic temperature compensation; cell constant adjustable on the display |
Choose this meter for routine teaching and water-testing work where a set of spare cells is useful. The microcontroller model suits users who want automatic ranging and temperature compensation, and the laboratory and field model is listed with a platinum dip-type cell. All three share the same product name, so quote the product code when you enquire.
What Is a Digital Conductivity Meter Used For?
Conductivity shows how readily a solution carries an electric current, which depends on the ions dissolved in it. Chemistry departments use the meter to compare strong and weak electrolytes and to follow conductometric titrations, topics met in class 12 electrochemistry and in college physical chemistry. Water, environmental and agriculture labs use it to check the purity of distilled water, the dissolved salts in drinking or irrigation water, and soluble salts in soil extracts. Choosing the cell matters: a low cell constant such as 0.1 suits very dilute, low-conductivity samples, while a constant of 1 suits most general solutions.
Calibrate with a standard potassium chloride solution, rinse the cell with distilled water before and after each sample, and keep the cell wet or stored as the operation manual directs. Conductivity rises with temperature, so record the sample temperature or measure all samples at the same temperature. Cover the meter with its dust cover when not in use.
What to Specify When Ordering
- Range and units — confirm the measuring unit and the five range steps you need, for example for pure-water work or saline samples.
- Cells — state which cell constant you want fitted and which spares (1, 0.5 or 0.1) to include.
- Quantity — the minimum order is 10 units.
Frequently Asked Questions
What range does this conductivity meter cover?
0 to 1000 in five ranges. The listing writes the unit as mhos/cm; a closely matching JLab model is listed at 0–1000 mS/cm, so confirm the exact unit and range steps with JLab before ordering.
How accurate is it?
The listed accuracy is ±1% of full scale ±1 digit, read on a 3½-digit LED display.
Which conductivity cells are available?
Spare cells with constants of 1, 0.5 and 0.1 are listed. Use the lower constants for dilute, low-conductivity samples such as distilled water.
Does it have automatic temperature compensation?
The listing does not say. If you need it, ask JLab, or compare the microcontroller model, which lists automatic temperature compensation.
What information is needed for an export quotation?
The quantity, destination country and port or city, preferred delivery terms (for example FOB or CIF), the mains voltage at site, and any tender reference.
Who manufactures this meter?
Jain Laboratory Instruments Pvt Ltd, trading as JLab, at its works in Ambala, Haryana, India.
OEM Manufacturer
JLab is the trading name of Jain Laboratory Instruments Pvt Ltd, a manufacturer of laboratory instruments and chemistry lab equipment in India, incorporated in 2017 and based on Hargolal Road, Ambala, Haryana. The meters are assembled at JLab’s own works rather than bought from a trader, so schools, colleges, testing labs and dealers buy factory-direct, each meter is visually inspected before dispatch, and spare cells and repeat orders are handled by the manufacturer. JLab exports worldwide and ships to buyers in every region — for example Germany in Western Europe, Algeria in North Africa, Bhutan in South Asia, Denmark in Northern Europe and Thailand in Southeast Asia. Tender information is on the JLab lab tenders page.
Related Water-Testing Instruments
- Digital pH, Conductivity & Temperature Meter — one instrument for pH, conductivity and temperature, with a 3½-digit red LED display.
- Digital Conductivity Meter — laboratory and field models with a platinum dip-type cell.
- Digital Conductivity Meter — microcontroller model with automatic ranging.
See the full Educational Laboratory Apparatus range or the wider Laboratory Apparatus section.
Request a Quote
Quotes come direct from the manufacturer. Use the Add To Cart enquiry button or the contact page and send the quantity (minimum 10 units), the range and cells you need, your mains supply and your delivery location.
Last updated: 9 October 2026