Digital Thin-Layer Chromatography Imaging System Manufacturer,Supplier and Exporter in India

Digital Thin-Layer Chromatography Imaging System

Product Code : EL-MM-10561
Jlab Export is a leading Digital Thin-Layer Chromatography Imaging System Manufacturer,and suppliers in India

Once a TLC plate has been developed, this system photographs it and analyses it on a computer. JLab supplies it with an imaging chamber, a camera, selectable illumination with shielding, and the analysis and export software. The software gives multi-spectral scans, calibration curves and graphical analysis of each spot, and saves password-protected reports as PDF files.

Specifications

PurposePC-based documentation and analysis of TLC plates
Scope of supplyImaging chamber, camera, selectable illumination with shielding, analysis and export software
AnalysisMulti-spectral scans, calibration curves, interactive graphical analysis
Image toolsImage refining, image documentation, comparison of several images
ReportsCustomisable reports, search of stored reports, data export in PDF format
AccessPassword protected, keyboard shortcuts
CalibrationInbuilt calibration mode for periodic calibration
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
Supplied byJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

TLC Experiments for Chemistry and Biochemistry

In thin layer chromatography, a small spot of sample moves up a thin layer of silica gel on a plate as the solvent rises through it. Different compounds travel different distances, and the Rf value is the distance moved by the spot divided by the distance moved by the solvent front.

A favourite college practical separates the pigments of a leaf extract. Students apply small spots with Glass Capillary Tubes for TLC Spotting and develop the plate in a closed Chromatographic Jar. The plate is then imaged on this system to record the green and yellow bands and work out each Rf. Biochemistry classes run amino acid mixtures and show the spots with Ninhydrin Sol (Test Of Amino Acids) before imaging.

Frequently Asked Questions

Does this system run the TLC plate itself?
No. Spotting and developing are done on the bench in the usual way. The system takes over once the plate is dry, imaging it and analysing the spots on a PC.

How is the Rf value measured from the image?
Rf is the distance moved by the spot divided by the distance moved by the solvent front. Mark the front with a pencil as soon as the plate comes out of the jar, because it fades as the solvent dries.

What can I do with the calibration curves?
Run standards of known amount beside the sample on the same plate. The software relates spot response to amount, so the amount in the sample spot can be estimated from the curve.

Which student mistakes show up clearly in the images?
Overloaded spots that streak, a starting line set below the solvent level, uneven fronts from a jar that was not closed, and smudged spots from touching the layer. Saved images make these easy to discuss afterwards.

How are results stored and shared?
Each plate image is saved with its analysis in a report. Reports can be laid out to suit the lab, searched later and saved as PDF files. The system is password protected.