Gas Chromatograph Manufacturer,Supplier and Exporter in India
Product Code : EL-ELA-5332
Jlab Export is a leading Gas Chromatograph Manufacturer,and suppliers in India
Gas Chromatograph (code EL-ELA-5332) is a laboratory gas chromatography system with a 12-litre column oven programmable from ambient to 400 °C, dual flame ionization detectors (FID) and a programmable 12-vial headspace unit, used to separate and measure volatile compounds in college, university and research laboratories. It is made by Jain Laboratory Instruments Pvt Ltd (JLab) at its works in Ambala, India.
Specifications
| Parameter | Detail |
|---|---|
| Column oven temperature range | Ambient to 400 °C in 1 °C steps |
| Column oven size | 12 litres |
| Temperature programming | Zero to 25 °C/min, set in 0.1 °C steps |
| Ramps | Four ramps with five isothermal holds |
| Oven cooling | Automatic cooling system for fast cool-down |
| Injector body | Stainless steel body that fits into a universal heated injector base |
| Glass insert | Removable |
| Injector port | Dual vertical port, for fused silica capillary columns or packed columns |
| Injector temperature | Ambient to 390 °C in 1 °C steps, set by thumbwheel switches |
| Number of injectors | Up to 3 (2 standard) |
| Injector types | Split/splitless and packed (packed is standard); packed sizes listed as 1/8 and ½ |
| Pressure control | Electronic pressure controls |
| Detectors | Dual flame ionization detectors with control module |
| FID jet | Quartz jet, which minimises degradation and absorption of samples |
| FID sensitivity | Better than 2 x 10^-12 g/s |
| FID amplifier | Dual differential type; amplifier sensitivity 2 x 10^-12 A/mV; linearity 10^7 |
| Output attenuator | Binary steps x1, x2, x4, x8, x16, x32, x64, x128, x256, x512, x1024 |
| Detector operation | All FIDs can be operated simultaneously on an identical sample |
| Construction | Modular, with separate modules for the microprocessor, FID and interface, for ease of servicing |
| Headspace | Programmable headspace unit for 12 vials |
| Power requirement | 230 V, 50 Hz, 2 kVA |
| Weight | 40 kg |
| Quality check | Each gas chromatograph is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 7–10 working days |
| Product code | EL-ELA-5332 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
What Is the Gas Chromatograph Used For?
Gas chromatography separates the components of a mixture that can be vaporised without breaking down. The sample is injected into a heated inlet, carried through the column by an inert carrier gas, and each compound leaves the column at its own retention time, where the flame ionization detector produces a signal in proportion to the amount of organic (carbon-containing) material reaching the flame. Typical teaching and research work includes analysing solvent mixtures, alcohols, essential oils, fatty acid esters and fuel fractions, and the headspace unit lets students sample the vapour above a liquid or solid held in a sealed vial, a common way to check residual solvents or volatile content without injecting the sample matrix. These are standard experiments in BSc and MSc instrumental analysis, pharmacy and food-science courses, and in university and research laboratories.
The temperature programme (zero to 25 °C/min with four ramps and five isothermal holds) lets one run cover compounds with a wide range of boiling points, and the dual vertical port injector takes either fused silica capillary columns, which give sharper separation of complex mixtures, or packed columns, which tolerate larger sample loads. Good practice is to establish carrier gas flow before heating the column, leak-check fittings after every column change, replace the inlet septum regularly and clean or change the removable glass insert when peaks start to tail. The FID burns hydrogen in air, so gas lines and cylinders should be installed by trained staff. Plan a bench that takes the 40 kg instrument and a mains supply rated for 230 V, 50 Hz, 2 kVA.
What to Specify When Ordering
- Injectors — the number you need (2 are standard, up to 3 can be fitted) and whether each should be split/splitless for capillary columns or packed.
- Columns, gases and data handling — the listing does not state that columns, gas cylinders or generators, or a computer and software are included, so list what you need and ask JLab to confirm.
- Headspace — confirm that you need the programmable 12-vial headspace unit with the instrument.
- Quantity and destination — the minimum order is 10 units; state the delivery location and any tender reference.
Frequently Asked Questions
What kind of samples can this gas chromatograph analyse?
Mixtures whose components can be vaporised without decomposing, such as solvents, alcohols, oils and fuel fractions. The flame ionization detectors respond to organic compounds, and the programmable headspace unit samples volatile compounds from liquids or solids held in sealed vials.
What is the maximum column oven temperature?
400 °C. The 12-litre oven is set from ambient to 400 °C in 1 °C steps, programmed at zero to 25 °C/min in 0.1 °C steps with four ramps and five isothermal holds, and an automatic cooling system brings it down quickly between runs.
Can it take both capillary and packed columns?
Yes. The dual vertical port injector accepts fused silica capillary columns and packed columns, with split/splitless and packed injector types; packed injectors are standard. Columns themselves are not listed as part of the instrument, so specify the columns you want in your enquiry.
How many injectors and detectors does it have?
Two injectors as standard, with room for up to three, and dual flame ionization detectors fed by a dual differential amplifier. All FIDs can be run at the same time on an identical sample.
How sensitive is the FID?
The detector sensitivity is listed as better than 2 x 10^-12 g/s, with linearity of 10^7 and a quartz jet that limits sample degradation and absorption. The output attenuator steps in binary multiples from x1 to x1024.
What power supply does it need?
230 V, 50 Hz, with a 2 kVA rating. The modular design keeps the microprocessor, FID and interface in separate modules, which makes servicing easier.
What information is needed for an export quotation?
Send the quantity, the destination country and port or city, your preferred delivery terms (for example FOB or CIF), the injector, column and headspace configuration you need, any packing or labelling requirements, and the tender reference if there is one.
Who manufactures this gas chromatograph?
Jain Laboratory Instruments Pvt Ltd, trading as JLab, builds it at its works in Ambala, Haryana, India, and quotes for it directly as the manufacturer.
OEM Manufacturer
JLab is the trading name of Jain Laboratory Instruments Pvt Ltd, a scientific instruments manufacturer in India incorporated in 2017 and based on Hargolal Road, Ambala, Haryana. The gas chromatograph is assembled at JLab’s own works rather than bought from a trader, so colleges, research laboratories, dealers and importers deal with the factory directly, every unit is visually inspected before dispatch, and repeat orders and spare modules are handled by the manufacturer. The company holds MSME Udyam registration UDYAM-HR-01-0003849 (manufacturing enterprise) and Importer-Exporter Code 3317504552. JLab exports worldwide and ships to buyers in every region — for example the USA in North America, Spain in Southern Europe, Namibia in Southern Africa, Afghanistan in South Asia and Papua New Guinea in Oceania. Tender details are on the JLab lab tenders page.
Related Analytical and Chromatography Equipment
- High Performance Liquid Chromatography — liquid-phase chromatography, listed with binary and quaternary system options, for samples that are not volatile enough for GC.
- Liquid Chromatography Digital System — an HPLC system listed with quaternary or binary pumps, a vacuum degasser and a column compartment.
- UV-VIS Spectrophotometer — for absorbance-based concentration measurement and spectrum scanning in the same instrumental analysis lab.
- Paper Chromatography Kit Portable — a Bakelite chromatography cabinet with accessories for teaching the separation principle and Rf values.
See more instruments in the Educational Laboratory Apparatus range or the full Laboratory Apparatus range.
Request a Quote
Quotes come direct from the manufacturer. Use the Add To Cart enquiry button on this page, or send the quantity (minimum 10 units), the number and type of injectors, the columns and headspace option you need, and your delivery location through the contact page.
Last updated: 9 October 2026