R-410A is a blend, so it is charged as liquid, and on a running unit that liquid must turn to vapour before it reaches the compressor. This adapter does that at the 5/16 in service port found on R-410A and R-32 equipment. It converts the liquid to saturated vapour as it passes into the low side.

Specifications

Size 5/16 in
Function Turns liquid refrigerant into saturated vapour
Use Charging blends
Minimum order quantity 10 units
Dispatch time Usually 4–6 working days
Manufacturer JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Workshop Exercises on R-410A Units

Once the R-410A Split Air-Conditioner has been evacuated, students top it up with R-410A Refrigerant. The cylinder is set to give liquid and stood on the Wireless Refrigerant Charging Scale. The adapter goes in the charging line at the 5/16 in suction port.

With the compressor running, students open the cylinder valve a little at a time and watch the suction pressure. They stop at the charge on the rating plate, then record suction and liquid line readings for the class log.

Frequently Asked Questions

Is R-410A really a blend?
Yes. R-410A is a near-azeotropic mix of R-32 and R-125. The two parts stay close together in use, but it is still charged as liquid so that the mix inside the system matches its design.

Is the adapter needed for R-32?
R-32 is a single refrigerant, so its make-up does not change when it is charged as vapour. The adapter still fits R-32 ports and feeds liquid at a steady rate, which shortens a top-up from a cylinder that is cooling down.

How does it differ from the 1/4 in version?
Only the size changes. This one suits the 5/16 in ports on R-410A and R-32 equipment. The Liquid Charging Adapters 1/4 suits standard 1/4 in ports on R-404A, R-407C and other systems.

What happens if liquid goes in too fast?
Even through the adapter, a fast feed can carry liquid toward the compressor and push the suction pressure up. Open the cylinder valve in small steps, keep an eye on the low-side gauge and pause if the pressure jumps.