Paper Electrophoresis Kit Chamber Manufacturer,Supplier and Exporter in India
Product Code : EL-RE-5129
Jlab Export is a leading Paper Electrophoresis Kit Chamber Manufacturer,and suppliers in India
Paper electrophoresis separates charged molecules, such as amino acids and proteins, on a strip of buffer-wetted paper between two electrodes. This chamber is the buffer tank for that work. The strip is laid across it with each end dipping into the buffer at one electrode, and a separate power supply drives the current through the paper.
Specifications
| Type | Paper electrophoresis chamber |
| Use | Separating charged molecules on buffer-wetted paper |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Biochemistry Practicals on Paper
A common college practical separates a mixture of amino acids. Students draw a start line in pencil across a strip of Chromatography Paper and wet it with buffer. They apply small spots of the mixture and of known amino acids, lay the strip in the chamber and close the lid. The run is powered by an Electrophoresis Power Supply, Digital, Variable set as the practical sheet directs.
After the run, the strip is dried and sprayed with Ninhydrin Sol (Test Of Amino Acids), and gentle warming shows the amino acids as purple spots. Students compare how far, and in which direction, each spot moved. Serum proteins can be run the same way as a teaching exercise, giving separate albumin and globulin bands.
Why Molecules Move on the Paper
An amino acid carries a charge that depends on the buffer pH. Above its isoelectric point it is negative and moves towards the anode. Below it, the molecule is positive and moves towards the cathode. At the isoelectric point it has no net charge and stays on the start line. Size and shape change the speed as well.
Frequently Asked Questions
Why must the start line be drawn in pencil?
Ink contains dyes that dissolve in the buffer and move in the electric field, giving false spots. Pencil graphite stays where it is drawn, so the line is still there to measure from after staining.
Why is the lid kept closed during a run?
The current warms the paper, and buffer evaporates from it. With the lid closed, the air above the strip stays moist, so the paper does not dry at the edges. Switch off the power supply before opening the lid.
Why did my spots streak instead of staying round?
Too much sample went on, or the paper was too wet or too dry. Apply small spots and let each one dry before adding more. Blot the wetted strip so that no buffer stands on its surface.
Which way will an amino acid move?
That depends on the buffer pH and the isoelectric point of the amino acid. In a mildly alkaline buffer most amino acids are negative and move towards the anode. Basic amino acids such as lysine are still positive and move towards the cathode.
How is it different from paper chromatography?
In chromatography a solvent climbs the paper and separates substances by how they share between solvent and paper. In electrophoresis the paper stays wet with buffer, and an electric field moves the charged molecules, so the separation depends on charge.
Other Electrophoresis Apparatus
- Gel Electrophoresis System
- Vertical Electrophoresis System
- Horizontal Electrophoresis System
- Electrophoresis Accessories
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 6 November 2026