• +91-85699-09696

Horizontal Electrophoresis System Manufacturer,Supplier and Exporter in India

Horizontal Electrophoresis System

Product Code : EL-GLE-4002
Jlab Export is a leading Horizontal Electrophoresis System Manufacturer,and suppliers in India

Horizontal gel electrophoresis separates DNA fragments in an agarose gel that lies flat under buffer. When current flows, the negatively charged fragments move towards the positive electrode, and smaller fragments travel further. This system separates DNA and RNA by size and shape. It has platinum electrodes of very high purity and comes with a gel casting tray, one comb and a terminal lead.

Specifications

UseSeparation of DNA and RNA in agarose gels
ElectrodesPlatinum, of very high purity
Supplied withGel casting tray, one comb and terminal lead
DesignSpace saving
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Biotechnology Practicals: Running a DNA Gel

Students melt agarose in buffer on a Magnetic Stirrer Cum Hot Plate and pour it into the casting tray with the comb in place. Once the gel has set, they take out the comb and lay the gel in the tank under buffer. Then they load their DNA samples and a size ladder with a Variable Volume Micropipette.

The run is powered by the Digital Electrophoresis Power Supply at a steady voltage. After staining, the bands are viewed on a U.V. Transilluminator. Students then estimate the size of each fragment against the ladder, or check a plasmid digest against the expected pattern.

Frequently Asked Questions

Why are my DNA bands smeared or blurred?
Common causes are a voltage high enough to heat the buffer, too much DNA in the well, degraded samples or old buffer. Run at a moderate voltage, load less DNA and use fresh buffer made up the same way as the gel.

Why are the bands wavy or bent?
Usually the agarose was not fully dissolved, or the gel set unevenly. Heat until the solution is completely clear with no floating specks, pour on a level surface and let the gel set fully before pulling the comb.

Can the running buffer be reused?
Only for a run or two of routine checks. Each run uses up some of the buffer and changes its ion content, which gives fuzzy bands and slower runs. Change it before any gel whose result you need to record.

Which end should the wells be at?
At the negative electrode, usually the black lead. DNA carries a negative charge and moves towards the positive, red electrode, so wells at the wrong end send the samples out of the gel into the buffer.

How do students load samples without damaging the wells?
Mix each sample with a dense loading dye so it sinks. Hold the tip just inside the well under the buffer, without piercing the bottom, and push the sample out slowly. Practice on a spare gel saves good samples.

Other Electrophoresis Apparatus

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us