Pyrogen Testing Instrument Manufacturer,Supplier and Exporter in India

Pyrogen Testing Instrument

Product Code : EL-GLE-4025
Jlab Export is a leading Pyrogen Testing Instrument Manufacturer,and suppliers in India

This eight-channel electronic thermometer follows body temperature during the pyrogen test, with one probe for each animal. A microprocessor scans the channels in turn or lets the operator step through them by hand. The 4 digit LED display shows each reading with its channel number. Grade A PT-100 platinum sensors read from 30.0 to 45.0 °C in steps of 0.1 °C.

Specifications

Channels8, with channel indication
ScanningAuto or manual, microprocessor based
Display4 digit LED
Range30.0 to 45.0 °C
Resolution0.1 °C
SensorGrade A PT-100 platinum
Probes supplied8 veterinary probes
Power220 V AC ±10%, 50 Hz
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Quality Control Practicals in Pharmacy Colleges

In B.Pharm and M.Pharm quality control courses, the pyrogen test is taught as a check on injections for fever-causing substances. The instrument logs the body temperature on a separate channel for each animal, and students plot every channel against time to read the rise. Institutions run this test under the approval of their animal ethics committee, and many courses now teach it alongside the bacterial endotoxin test.

A first exercise needs no animals at all. Students place all eight probes in a stirred Water Bath Precision and compare each channel with a Digital Stem Thermometer held beside them. A channel that reads apart from the rest is noted before the instrument goes into use, and the same set-up shows how long a probe takes to settle.

Frequently Asked Questions

Why does the pyrogen test need readings to 0.1 °C?
The test looks for small rises in body temperature over the test period. A display that steps in 0.1 °C shows those changes, while coarser readings would hide them.

What is the difference between auto and manual scanning?
In auto mode the microprocessor steps through the 8 channels in turn and shows each reading with its channel number. In manual mode you pick the channel yourself, which suits a quick check of one probe.

How long should a probe settle before a reading is noted?
Wait until the display stops changing. A platinum sensor needs a short time to reach the temperature around it after it is placed or moved. The test method used in your lab sets this waiting time, so follow your own method sheet.

Can it be used on large animals as well?
Yes. Besides pyrogen work on small laboratory animals, it is used to take the temperature of larger animals such as cattle, buffaloes and camels, with the veterinary probes supplied.

Is the rabbit pyrogen test still used?
It is still run in some labs, but many products are now tested with the bacterial endotoxin test, and some with the monocyte activation test. The rabbit test stays in use where pyrogens other than endotoxin must be detected.