Redwood Viscometer Apparatus Manufacturer,Supplier and Exporter in India
Product Code : EL-GLE-4009
Jlab Export is a leading Redwood Viscometer Apparatus Manufacturer,and suppliers in India
A Redwood viscometer gives the viscosity of an oil as the time a set volume takes to flow out through a standard orifice at a set temperature. The result is quoted in Redwood seconds. The oil cup stands in a heated bath, and a ball valve opens and closes the orifice at the start and end of each run.
Specifications
| Type | Redwood efflux viscometer |
| Measures | Flow time of oil through a standard orifice, in Redwood seconds |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Viscosity Experiments in Fuels and Lubricants Labs
Students find the Redwood seconds of a lubricating oil at several temperatures, timing each run with a Digital Stop Watch, and plot flow time against temperature. The same oil can then be run on the Saybolt Viscometer to compare the two empirical scales. Teachers may add a kinematic viscosity test with glass capillaries in the Viscometric Water Bath.
Frequently Asked Questions
What is the difference between the Redwood I and Redwood II viscometers?
Both work the same way. Redwood I has the smaller orifice and suits thinner oils. Redwood II has a larger orifice for heavy oils that would take far too long to run through the smaller jet.
How does a Redwood viscometer differ from a Saybolt?
Both time a set volume of oil through a standard orifice at a set temperature. The Saybolt uses its own orifices and receiving flask and reports Saybolt seconds, so the two readings cannot be swapped without conversion tables.
When do I start and stop the stopwatch?
Start it the moment you lift the ball valve to open the orifice, and stop it when the oil in the receiving flask reaches the mark. Starting late or early is the commonest timing error in student results.
Why should air bubbles be removed and the orifice kept clean?
Bubbles and dirt change the flow through the narrow jet, so the oil runs slowly or unevenly. Let bubbles rise before the run, and clean the orifice after each oil with solvent and a soft brush, never a wire.
Why does the flow time fall as the oil is heated?
A liquid gets thinner as it warms, because its molecules slide past each other more easily. Plotting flow time against temperature shows how fast an oil thins, which is what the viscosity index of a lubricating oil describes.
Other Viscometers
For a quote, use Add To Cart or send us a message through the contact page.